814949
19
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
19
KOBE - FENICE - SPARK - INDACO - PRINCE - GO - ECLIPSE
8.11 PROGRAMMED MODE TIMER  MAIN MENU
Setting the current day and time is essential for the proper operation of the timer.
There are six TIMER programmes, for each one the user can decide the start-up and shutdown time as well as the day of the week
in which it is active.
When one or more programmes are active, the panel alternately displays the boiler status and TIMER n” whereby “n is the number
relating to the activated timer programmes, separated from each other with a dash
Example:
TIMER 1 Timer programme 1 active.
TIMER 1-4 Timer programmes 1 and 4 active.
TIMER 1-2-3-4-5-6 Timer programmes all active.
EXAMPLE OF PROGRAMMING
With boiler on or off:
access the MENU,
scroll to TIMER with the <> arrows,
press the “Menu” key
the system proposes “P1” (Press the <> keys for the subsequent timers P2,P3, P4, P5, P6)
to activate “P1” press the “Menu” key
press + - and select “ON”
confirm with the “Menu key
At this point it will propose 00:00 as starting time, with key + - adjust the starting time and press the “menu key to confirm.
The next step proposes a shutdown time of 10 minutes above that set for start-up: press the + key and adjust the shutdown time,
confirm with the “menu key.
Subsequently the system proposes the days of the week in which to activate or deactivate the previously set timer. With the - or +
key highlight with the white background the day in which one wishes to activate the timer and confirm with the menu” key. If no
day of the week is confirmed as active, in turn the timer programme will not appear active in the status screen.
Continue to program the following days or press “ESC to exit. Repeat the procedure to program the other timers.
8.12 PROGRAMMING EXAMPLES:
P1 P2
on off day on off day
08:00 12:00 mon 11:00 14:00 mon
Boiler on from 08:00 to 14:00
on off day on off day
08:00 11:00 mon 11:00 14:00 mon
Boiler on from 08:00 to 14:00
on off day on off day
17:00 24:00 mon 00:00 06:00 tue
Boiler on from 17:00 on monday to 06:00 on tuesday
8.13 NOTES FOR TIMER OPERATION
Start-up with the timer always takes place with the last temperature and ventilation settings (or with default 20°C and V3
settings in the event they have never been changed).
It is possible to set the shutdown time from “ignition time + 10 minutes” up to 23:50. If 24:00 is set as shutdown time, the stove
will not switch off (use this shutdown time, for example, when the next day is programmed to continue from 00:00).
If the shutdown time is not already memorised, it proposes a start-up time in + 10 minutes.
A timer programme switches the boiler off at 24:00 of one day and another programme switches it on at 00:00 of the next day:
the boiler stays on.
A programme proposes a start-up and shutdown in times included within another timer programme: if the boiler is already on,
start will not have any effect, while OFF will switch it off.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cadel INDACO 11 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Cadel INDACO 11

Cadel INDACO 11 Bedienungsanleitung - Deutsch - 37 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info