696340
27
Zoom out
Zoom in
Vorherige Seite
1/44
Nächste Seite
11
KRISS
3
- TECNA
3
- EVO
3
- ELISE
3
- SHELL
3
- CRISTAL
3
- GLASS - VERVE AT - PRETTY AT - TITANIA AT - VENERE AT - BREEZE AT
Air Fan Voltage
Screw Loading
Fire
8.6 START UP
We remind you that the first ignition must be carried out by a specialized and authorixed technician who will check that all is
installed in compliance with current regulations and checks the efficiency.
If inside the combustion chamber there are booklets, manuals, etc..., remove them.
Check if the door is correctly closed.
Check if the stove is correctly inserted in the electric socket.
Before switching the stove on, assure you the burning pot is clean.
To start the stove, keep the P1 button pressed until the ON sign and a flashing flame to its side appear. The ignition resistance
pre-heating starts. After some seconds the feed screw loads pellets and the resistance pre-heating continues. When the tem-
perature is high enough (after about 5-8 minutes), ignition is considered to be completed.
Once the ignition step is complete, the stove moves into operating mode and shows the selected heat output, the ambient
temperature and the big flame (see Fig. 6).
If the ambient temperature value exceeds the limit set on the button panel in the temperature set, the heat output is brought
to its lowest value and the small flame is shown (see Fig. 7). When the ambient temperature decreases below the set tem-
perature, the stove goes back to the set output.
Fig. 4 - Big ame Fig. 5 - Small ame
8.7 FAILED IGNITION
If pellets should not ignite, the lack of ignition will be signalled by the A01 "No Ignition" warning.
If the ambient temperature is below 5°C, the resistance may not heat up enough to guarantee the pallet ignition. In this case,
remove the unburned pellets from the burning pot and restart ignition.
Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difficult and create dense white
smoke which is harmful to health and can cause explosions on the combustion chamber. It is therefore necessary not to stand
in front of the stove during ignition stage if dense white smoke is present.
If after some months the flame appears weak and/or orange colored or the glass tends to blackens and the
burning pot to become encrusted, clean the stove, clean the fume conduit and the chimney flue.
8.8 SWITCH OFF ON PANEL: OFF WITH FLASHING FLAME
If the shutdown key is pressed or if there is an alarm signal, the boiler goes into the thermal shutdown phase which entails the
automatic execution of the following stages:
Pellet loading is stopped.
The room fan continues to operate until the requested temperature is reached.
The flue fan is set to its highest value, which it keeps until the requested temperature is reached, plus a safety time of 10
additional minutes. After that, if the fume temperature has decreased below the switch off threshold, it stops, otherwise the
cooling process goes on.
If the stove has switched off normally, but owing to thermal inertia, the fume temperature goes over the threshold again, the
switch off process is reactivated until the temperature decreases again.
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cadel Shell 3 - 2019 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Cadel Shell 3 - 2019

Cadel Shell 3 - 2019 Installationsanweisung - Deutsch - 48 seiten

Cadel Shell 3 - 2019 Bedienungsanleitung - Deutsch - 44 seiten

Cadel Shell 3 - 2019 Installationsanweisung - Englisch - 47 seiten

Cadel Shell 3 - 2019 Installationsanweisung - Holländisch - 48 seiten

Cadel Shell 3 - 2019 Bedienungsanleitung - Holländisch - 44 seiten

Cadel Shell 3 - 2019 Installationsanweisung - Französisch - 60 seiten

Cadel Shell 3 - 2019 Bedienungsanleitung - Französisch - 44 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info