Page 14
operatInG InStructIonS
MAIN CONTROL PANEL
The main control panel provides a quick visual check of the spa’s status
and allows the user to set the temperature, activate the jets & lights, lock
the temperature and/or spa functions. Other optional functions may also
be available depending on the spa model and accessory equipment that
has been installed into the spa. The main control panel has eight buttons.
HARD BUTTONS
The four labeled outer buttons are referred to as "Hard buttons". These
buttons are fixed and their functions do not change.
JETS - If jet pump indicator light is off and JETS hard button is pressed,
the 1st jet pump function will activate and the main control panel display
will advance to the Jets menu.
If jet pump indicator light is on and the JETS hard button is pressed while
in any screen other than the Jets menu, the jets pump function does not
change, only the main panel screen will change to the Jets menu.
LIGHTS - If lights are off, press LIGHTS hard button from any screen
to turn on all lights and display the Lighting Options menu. Continue to
press the LIGHTS hard button to cycle through lights zones.
OPTIONS - Transitions to the Options screen to access temperature and
setup menu
BACK - Goes back one menu. In Home screen Hold BACK button until
screen rotates 180° to view from inside spa. Repeat to reverse.
SOFT BUTTONS
The four inside buttons are referred to as "soft buttons". Pressing a soft
button will activate the function on the control panel screen closest to that
button. After a period of non-use (45 seconds) the display will go back to
the Home screen and will remain on for several minutes before going to
sleep mode. Pressing any button will wake up a sleeping display.
INDICATOR ICONS
At a glance, the indicator icons are visible on the main control panel.
The indicator icons work independently from the rest of the control panel
display. They are displayed so that you may know the status of your spa
at a glance. NOTE: Indicators will not be visible when Main Control Panel
goes into sleep mode.
READY Indicator: The READY indicator will display when the
spa water temperature is within 1°C (2°F) of the set
temperature, and will turn off when the temperature is outside of
that range. If you increase or decrease the temperature setting
of the spa, the ready indicator will turn off until the water
temperature reaches the acceptable range for the new
temperature setting. A flashing READY indicator means a
problem may exists with the temperature sensor (see
Troubleshooting section for more information)
Spa Light Indicator: The Spa Light indicator is displayed when
any light inside the spa is on. The indicator icon will remain solid
as long as any manual light is activated.
Spa or Temperature Lock Indicator: The Spa or Temperature
Lock indicator is displayed when either the Spa Lock,
Temperature Lock or both are activated. Lock indicator does not
flash.
Jet Pump Indicator: The Jet Pump indicator is displayed
whenever a jet pump is on. The Jet Pump indicator will flash
whenever the spa is in the ten-minute Clean Cycle or Auto
Clean Cycle.
Summer Timer Indicator: The Summer Timer indicator is
displayed when the summer timer is set to ON. In summer timer
mode, the heater and circulation pump cycle are off for eight
hours. The Summer Timer indicator will not flash.
POWER Indicator: The POWER indicator is ‘on’ when the spa
is properly supplied with power. It also provides a diagnostic
function–a flashing power indicator indicates that the heater high
limit has tripped, meaning that either the spa water is above its
acceptable temperature range, or a malfunction has occurred
within the spa (such as low circulation due to clogged filters).
When the power indicator is not displayed it means that there is
a problem with the spa control box or the power supplied to the
spa (see Troubleshooting section for more information).
HOME SCREEN
The temperature displayed in the center of the Home screen is the actual
temperature of the spa water. If the READY icon is displayed and solid on
the control panel, then the actual spa temperature is within 1°C (2°F) of
the set temperature. The corner soft button functions are as follows:
MEMORY
This feature will recall the last active
setting for jets and lights prior to
pressing the All Off button.
ALL OFF
This feature will shut jets, lights and
audio (if installed) off immediately, while saving the last active jets and
lights settings.
JETS Hard Button
Soft Button Soft Button
LIGHTS Hard Button
OPTIONS
Hard Button
BACK
Hard Button
Indicator Icons
Operating Instructions
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Caldera Paradise - serie 2022 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Caldera Paradise - serie 2022

Caldera Paradise - serie 2022 Bedienungsanleitung - Deutsch - 44 seiten

Caldera Paradise - serie 2022 Bedienungsanleitung - Holländisch - 44 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info