• Reset GFCI; call for service if it will not reset
• Disconnect power for at least thirty seconds to reset heater high limit. If it will not
reset, check for clogged filters. If tripping continues, call for service.
• Deactivate spa lock
Spa does not heat; jets and light
operate (Orange logo "Ready", and
Gray logo "Power" indicators are
blinking)
• Integrated pressure switch open
• Circulation pump thermal cut-off tripped
• Check for clogged filters. Integrated pressure switch will reset when the flow of water
through the heater has been restored. Call for service if the heater trips frequently.
• Check for clogged filters or air locks in plumbing. Disconnect power to the spa, allow
circulation pump to cool. Circulation pump thermal cut-off will reset when pump has
cooled and power is reapplied. Call for service if circulation pump thermal cut-off
trips frequently.
Jets weak or surging• Spa water level too low
• Filters clogged
• Air valves are closed
• Add water
• Clean filters
• Open air valves
Lights inoperative
• Spa lock activated
• Light wiring or assembly is faulty
• Deactivate spa lock
• Call for service, replace light assembly
Spa not heating properly• Temperature set too low
• Spa cover improperly positioned
• Dirty Filter
• Summer Timer On
• Set control panel to a higher temperature.
• Align spa cover
• Clean filter
• Turn summer timer mode to off position
Gray Logo "Power" indicator blinking• Heater high-limit thermostat tripped• Disconnect power for at least thirty seconds to reset heater high limit. If it will not
reset, check for clogged filters. If tripping continues, call for service.
Orange Logo "Ready" indicator
blinking
• Temperature sensor problem• Disconnect power for at least thirty seconds. If blinking continues, call for service.
Pump motor will not function• Motor overload condition
• Control switch failure if jet symbol does not
come on
• Let cool for one hour. Motor overload will reset automatically. If problem persists,
contact your CALDERA dealer
• Disconnect spa and contact your CALDERA dealer
Noisy pump or motor• Low water level• Add water to normal level (2.5 cm above highest jet)
Pump motor runs, but low or no water/
jet pressure
• Air control valve closed or blocked
• Low water level
• Dirty filter cartridge
• Jet blocked
• Clogged suction or skimmer basket
• Open or clean air valve
• Add water to normal level (2.5 cm above highest jet)
• Clean filter cartridge
• Remove jet face eyeball and clean orifice
• Clean suction cover or skimmer basket
Diverter valves are difficult to turn
• Sand or grit inside valves
• Clean and lubricate valve per diverter valve maintenance instructions.
After filling or refilling the spa: a jet
pump is operating, but water is not
flowing from any of its jets
• Pump is not properly primed
• Turn off power to the spa at the breaker and remove the equipment compartment
door.
• Loosen the union on the top of the pump(s) to allow the air to escape, and then
hand-tighten the union(s).
• Turn power back on, activate the pump, and check to make sure the union is tight
enough to keep it from leaking. Replace the equipment doors.
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Caldera Utopia - serie 2018 wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.