electrIcal requIrementS
ELECTRICAL
Your CALDERA spa has been carefully designed to give you maximum
safety against electrical shock. Connecting the spa to an improperly
wired circuit will negate many of the spa’s safety features. Improper
wiring may also cause electrocution, risk of fire, and other risks of
injuries. Please read and follow the electrical installation requirements
and instructions for your spa completely! Your spa must be supplied by
a residual current device (RCD) - with a tripping rating not exceeding 30
mA in an electrical subpanel.
VACANZA SPAS MUST BE WIRED IN ACCORDANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. ALL
ELECTRICAL WORK SHOULD BE DONE BY AN EXPERIENCED,
LICENSED ELECTRICIAN. WE RECOMMEND THE USE OF
APPROPRIATE ELECTRICAL CONDUIT, FITTINGS, AND WIRE FOR
ALL CIRCUITS.
The MARINO, CAPITOLO, CELIO, VANTO and AVENTINE spas
require a 16 amp, single phase, 230 volt, three wire service (one line,
one neutral, one ground).
The AVENTINE can be converted to a 20 amp service allowing the
high speed jet pump to operate simultaneously with the heater. A
CALDERA Spa Technician must reconfigure spa using the soft jumpers
to allow the heater to run concurrent with jet pump.
The PALATINO spa requires a 20 amp single phase, 230 volt,
three wire service (one line, one neutral, one ground) found below.
Additionally, one main disconnect switch with at least 3 mm separation
between contacts must be used for all electrical circuits to the spa.
Mount the subpanel according to local codes, but not closer than 1.5
meters (5 feet) away.
CONDUIT INSTALLATION INSTRUCTIONS
1. To connect the electrical service, first remove the screws from the
equipment compartment door. Carefully pull the door panel down
and away in order to remove it completely from the spa.
2. Locate the control box. Loosen the screws on the front of the
control box. Remove the screws and the control box cover.
3. Route the electrical conduit through the access opening of the spa.
4. Connect the supply conduit to the control box and connect the
wiring as detailed below, or on the wiring diagram label on the
inside of the control box cover.
WARNING: Removing or bypassing any RCD breaker will result in an
unsafe spa and will void the spa’s warranty.
IMPORTANT: Should you ever find the need to move or relocate your
VACANZA spa, it is essential that you understand and apply these
installation requirements. Your VACANZA spa has been carefully
engineered to provide maximum safety against electric shock.
Remember, connecting the spa to an improperly wired circuit will negate
many of its safety features.
NOTE: Long wiring runs may require larger-gauge wire than stated.
230 VOLT 50HZ SUBPANEL WIRING
25A
16A
*20A *
* 20A ONLY
20A
6.0 mm2, Neutral, Blue
6.0 mm2, Ground, Grn/Ylw
6.0 mm2, Line, Brown
Less than 15 meters (50 ft.)
More than 1.5 meters (5 ft.)
Main Service
Electrical Panel
220-240 VAC
Single Pole Circuit
Breaker (Non
RCD)
Sub-Panel with
RCD breaker
Less than 30 meters (100 ft.)
Control Box
6.0 mm2, Neutral, Blue
6.0 mm2, Ground, Grn/Ylw
6.0 mm2, Line, Brown
12 Electrical
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Caldera Vacanza - serie 2020 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Caldera Vacanza - serie 2020

Caldera Vacanza - serie 2020 Bedienungsanleitung - Deutsch - 40 seiten

Caldera Vacanza - serie 2020 Bedienungsanleitung - Holländisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info