16 1005759 ISSUE 3
OWNER/INSTALLATION MANUAL
Electrolytic corrosion will occur when dissimilar metals
at are in contact wi each oer create a potential
difference between emselves. Sometimes separated
by a conductive substance known as an electrolyte, e
dissimilar metals will create a small voltage (potential
difference) at allows e ions of one material to pass
to e oer.
Just like a battery, ions will pass from e most positive
material to e more negative material.
Anying more an 0.3 volts can cause e most
positive material to degrade.
A swimming pool wi its associated equipment
can create is effect. The pool water being an ideal
electrolyte and components of e filtration circuit,
heating system, steps, lights etc providing e dissimilar
metals needed to complete e circuit.
Whilst ese small voltages are rarely a safety reat,
ey can create premature failure rough corrosion.
Not dissimilar to corrosion rough oxidation, electrolytic
corrosion can cause complete failure of a metallic
material in a very short period of time.
In order to prevent is type of corrosion all metallic
components in contact wi swimming pool water
should be bonded togeer using 10mm² bonding
cable. This includes non-electrical items such as metal
filters, pump strainer boxes, heat exchangers, steps
and handrails. It is highly recommended at bonding
be retrofitted to existing pools, which may not be
protected by is system.
All electrical work to be carried out in accordance wi
l.E.E.regulations, latest issue, or local codes of practice
as applicable. .
The machine should be installed in accordance wi
EMC2004/108/EC.
Always isolate e main ower supply before removing
machine covers.
The machine power supply must incorporate e
following. Fuses or motor type circuit breakers (aM
Fuse / MCB type C) to specified rating (see datasheet).
When using a fuse, H.R.C. fuses are recommended. An
isolator which disconnects all poles must be must fitted
wiin 2m and in line of sight of e heat pump. The
isolator must have a minimum of 3mm air gap when
turned off.
All units must be correctly eared/grounded and its
own separate type F RCD ear leakage trip installed
which protects e machine only.
The following limits of operation must not be exceeded.
Failure to provide e necessary voltages will invalidate
e warranty. This voltage must be available at e heat
pump whilst running. The voltage must not drop below
e above figures when starting e compressor.
Minimum Maximum
Voltage
Single phase machines 207V 253V
Cycle frequency (50Hz) 47.5Hz 52.5Hz
3�6 ELECTROLYTIC CORROSION IN SWIMMING
POOLS
3�7 ELECTRIC WIRING AND SUPPLY
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Calorex V-PAC inverter wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info