Once nished the unit will display a screen similar to the one below reporting
which speakers were found and any that appear out of phase.
Audyssey Autosetup Menu
Speakers Detected:
L :
C :
R :
RS :
RB :
LB :
LS :
SW :
Continue : [Enter]
Cancel/Return : I/O
Connected
Connected
Connected
Connected
Connected
Connected
Connected
Connected
If any speakers appear unconnected or out of phase carefully check the
connections on the speaker and the back of the unit. Also check any bi-wiring
links that might be present on the speaker. For any out of phase speakers
check that the relevant + terminal of the 751R V2 goes to the + terminal
of that speaker and similarly the terminal of the 751R V2 goes to the
terminal of the speaker for that channel.
Note: Like all such systems there are some limitations. Speakers that
exhibit very strong phase angles or deliberately wire some drive units out of
phase can of course appear to the system as an out of phase speaker when
correctly connected. If a speaker is reported as out of phase but is correctly
wired it is ok to proceed to the next step.
If necessary press the I/O button to cancel and perform a retest or press
Enter to start the second part of the autosetup procedure as below.
Audyssey Autosetup Menu
Speaker Calculation:
The unit is now
calculating parameters for
your speakers.
Percent: 50%
Again a series of test signals will now be output from all of the connected
speaker terminals and Subwoofer. The 751R V2 uses these to measure the
levels crossovers and distances (and hence introduce the correct delays)
appropriate to your speakers and room characteristics.
For Audyssey & 2EQ the unit will ask you to make a second measurement
after having moved the microphone to the left boundary of the normal
listening area occupied by yourself and other listeners (for instance the left
hand end of your sofa). Then a further measurement after having moved the
microphone to the right boundary of the normal listening area. In both cases
the microphone should be approximately at your normal listening height.
2 1 3
Audyssey 2EQ Room EQ
This is a more sophisticated version with a longer second stage that
measures the frequency response of all of your speakers three times at
three different points in the room and then calibrates and equalizes them
to optimise the sound for your actual listening environment (Room EQ).
To perform Audyssey autosetup with no Room EQ simply select Audyssey
autosetup from the menu. To perform autosetup and Room EQ select
Audyssey autosetup & 2EQ.
The process for both system is the same other than the extra sets of
measurements so we'll describe the Audyssey & 2EQ case only below.
a
zu
r
7
5
1
R
AV
Recei
v
e
r
Volu
m
e
P
hone
s
T
uning
M
od
e
/
S
tore
BD
/
DVD
US
BVi
deo
1
S
tere
o
M
ode
s
P
ic.
Ad
j.
Surroun
d
M
ode
s
Zon
e
2
Audi
o
Vide
o
S
-Vide
o
Audi
o
I
nput T
y
p
e
V
i
deo
2
Reco
r
de
r
1
A
ux
/
TV
C
D
Reco
r
de
r
2
Video
3
/
M
P3
+
S
tandb
y
/
On
7.1 Dir
ect
Analo
g
Ste
r
eo
Dir
ect
O
ptical
M
P3 In
T
u
n
e
r F
M
/
AM
E
x
p
ansio
n
H
DM
I
L
R
Mute
/
Inf
o
Digitally Processed Modes
Digitally Processed Modes
AudioL
First, connect the supplied microphone to the front Left front panel audio
input on the front panel via the supplied adaptor and place it at your normal
listening position in the room.
Press the OSD button on the remote control to access the OSD and then
select the Speaker Setup Menu. Now select the Audyssey option you want.
Speaker Setup Menu
Speaker Configuration
Speaker Level Calibration
Speaker Distance
Speaker Crossover
Audyssey Autosetup
Audyssey Autosetup & 2EQ
Return I/O
Follow the on-screen instructions and press 'Enter' on the remote control
when ready to start the Audyssey autosetup function.
Audyssey Autosetup Menu
Plug the microphone into
the left channel of Video
3 and place the microphone
at the main listening
position at listening
height.
Continue : [Enter]
Cancel/Return : I/O
Once activated the OSD will display the message below and the word
'Audyssey Auto Calibration' will also be displayed on the front panel of the
751R V2 to conrm.
Audyssey Autosetup Menu
The unit is now checking
which speakers are
connected, their phase,
crossover, level and
distance.
This will take several
minutes, please wait...
Left Speaker
A series of test signals will now be output from all of the connected speaker
terminals of the 751R V2 (including the Subwoofer output).
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cambridge Audio Azur 751R V2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Cambridge Audio Azur 751R V2

Cambridge Audio Azur 751R V2 Bedienungsanleitung - Deutsch - 40 seiten

Cambridge Audio Azur 751R V2 Bedienungsanleitung - Holländisch - 40 seiten

Cambridge Audio Azur 751R V2 Bedienungsanleitung - Französisch - 8 seiten

Cambridge Audio Azur 751R V2 Bedienungsanleitung - Italienisch - 40 seiten

Cambridge Audio Azur 751R V2 Bedienungsanleitung - Spanisch - 40 seiten

Cambridge Audio Azur 751R V2 Bedienungsanleitung - Polnisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info