Repair hints
Operation with closed fire box in accordance with EN 13229 Lina TV
5545 s/h
5551 s/h
5557 s/h
5580 h
Lina TV
6745 s/h
6751 s/h
6757 s/h
6780 h
Lina TV
7345 s/h
7351 s/h
7357 s/h
7363 s/h
Lina TV
8745 h
8751 h
8757 h
Lina TV
10045 h
10051 h
10057 h
Lina TV
12045 h
12051 h
12057 h
Nominal heat output kW 7 9 9 10 10 10
Thermal output range kW 3.4–7.4 3.2–10.9 3.2–10.9 4.6–10.1 3.2–10.9 4.9–10.6
Room heat output kW 7 9 9 10 10 10
Heat distribution: through the viewing window % 60 60 60 65 70 70
Heat distribution: convective output % 40 40 40 35 30 30
Suitable for multiple flue connections to the chimney 
Flue gas connector Ø inmm 180 200 200 200 200 250
Combustion air connector Ø inmm 125 125 150 150 150 150
SMR combustion control 
recommended free cross-section*Supply air (cm2) 840 1080 1080 1200 1200 1200
Recirculation air (cm2) 700 900 900 1000 1000 1000
Combustion air requirement m³/h 28 36 36 40 40 40
Recommended quantity of wood, approx. kg 3.0 4.0 4.0 4.5 5.0 5.0
Recommended quantity of wood with NHK, approx. kg --- 5.5 5.5 7.0 --- ---
Recommended quantity of wood with heat storage
system, approx. kg 5.5 5.5 6.0 --- --- ---
Recommended length of logs cm 33 33 33 33 33 33
Fuel conversion kg/h 5.1 5.3 4.7 --- --- ---
Minimum distance to the fire box
(in accordance with TR OL 2006, version 2010) mm 800 800 800 800 800 800
Minimum distance to the insulation
(in accordance with TR OL 2006, version 2010) mm 70 90 90 100 100 100
Insulation thickness (with awall that does not need to
be protected) (based on SILCA® 250KM) mm 60 60 60 60 60 60
Weight kg 200-260 220-280 230-290 280-320 310-350 340-400
Fuel Type Wood Wood Wood Wood Wood Wood
Triple values
with nominal
heat output
Flue gas mass flow g/s 6.4 9.1 9.1 8.9 10.1 7.9
Flue gas temperature °C 260 320 320 320 320 365
Required delivery pressure Pa 12 12 12 12 12 12
Triple values for connecting
ceramic flues
(wood used as fuel)
Firing power kW 18.2 18.2 19.8 --- --- ---
Flue gas mass flow g/s 15.1 29.6 16.7 --- --- ---
Flue gas temperature
upstream of the connecting surface °C 335 335 335 --- --- ---
Required delivery pressure at the flue
gas connector Pa 15 15 15 --- --- ---
Combustion air requirement m³/h 63.9 66.3 59.6 --- --- ---
Recommended flue length2m1,7 3,5 3,5 3,5 3,5 3,5
Emission
values
Wood fuel
CO - based on 13 % O₂ mg/Nm³ < 1250 < 1250 < 1250 < 1250 < 1250 < 1250
Dust - based on 13% O₂ mg/Nm³ < 40 < 40 < 40 < 40 < 40 < 40
Eiciency % > 80 > 78 > 78 > 78 > 78 > 80
Minimum heat-emitting surface3
(based on closed design) 2,5 2,7 2,7 3,0 3,0 2,4
Ecodesign Regulation in accordance with (EU) 2015/1185 
Energy eiciency class in accordance with (EU) 2015/1186
Energy eiciency index (EEI) 109.0 103.4 103.4 103.2 103.4 106.6
Declaration of Performance No. LE29102333 LE29061074 LE29061074-2 LE29102338 LE29061074-3 LE29102334
possible
connected
equipment
Top mounted heat exchanger --- --- --- --- --- ---
Hot air top-mounted element --- --- --- --- --- ---
Heat exchanger --- --- --- --- --- ---
Eiciency with connected equipment % --- --- --- --- --- ---
Hot water top-mounted element (HWAR R)
4
4--- --- --- ---
s = hinged door, h = guillotine door, TV = tunnel version
The specified waterside output was determined under test conditions. The achievable output can vary
depending on the flue liner, quantity of wood and pump assembly used.
1 The calculation was based on “TR OL 2006, edition 2010 – Table 17: Free cross-section in cm² for grille or
opening tile based on the thermal output for air heating” with the preferred air velocity of 0.75 m/s. Supply air
grille 240 cm2 / kW, recirculation air grille 200 cm² / kW.
2 The information regarding flue lengths is a recommendation and based on the
calculation in accordance with TR OL 2022 chapter 15. The calculation is based on a
medium-heavy design and a flue ratio of 360 cm².
4 With the exception of height 80 cm
3 Average value based on the storage time. Depending on the material properties
and the construction thickness.
Mean specific heat distribution = approx. 500 W /
29

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Camina-Schmid Lina wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Camina-Schmid Lina

Camina-Schmid Lina Bedienungsanleitung - Deutsch - 40 seiten

Camina-Schmid Lina Bedienungsanleitung - Holländisch - 36 seiten

Camina-Schmid Lina Bedienungsanleitung - Französisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info