GB
16
Flexible tubing connection: to connect the tubing to the
connector on the barbecue, tighten the nut on the tubing
firmly but without excess force using the two wrenches
provided:
- no. 14 wrench to tighten the connector
- no. 17 wrench to tighten the nut on the tubing
Check for leaks following the instructions in paragraph g.
f) LID
Handle the lid carefully, especially during operation. Do
not lean over the base.
g) CHECKING FOR GAS LEAKS
1) Work outside, away from all sources of ignition. Do not
smoke.
2) Make sure the control knobs are in the "off" (O)
position.
3) Connect the flexible tubing to the connector and
barbecue as described in part e).
4) Fit the regulator onto the gas cylinder in accordance
with its instructions.
5) Use a gas leak solution to test for leaks. Important:
never use a naked flame to check for gas leaks.
6) Apply the solution to the connections cylinder/
regulator/ hose/ apparatus (the control knobs should
remain closed: “off” position (O). Open the gas cylinder
valve.
7) Bubbles in the gas leak solution indicate that there are
gas leaks.
8) The leak can be stopped by tightening any hose
connection or replacing any faulty component. The
barbecue must not be used until the leak is stopped.
9) Close the valve on the gas cylinder.
Important:
Check for leaks at least once per year and each time the
gas cylinder is replaced.
h) PRIOR TO USE
Never use the barbecue until the instructions have been
read carefully and understood. Also, make certain that:
- there are no leaks
- the venturi tubes are not blocked (example: spider
webs)
- the hose does not touch
any components which
may get hot.
i) LIGHTING THE GRILL BURNERS (fig. 14)
Read steps 1 to 5 before beginning with step 1.
1) Never light the barbecue with the lid closed, only
with the lid open.
2) Make sure the control knobs are in the "off" (O)
position.
3) Open the gas cylinder valve.
4) Press one of the 2 control knobs and turn it to the full
flow ( ) position, then immediately press the igniter
button ( ) until you hear the click. Repeat 3 or 4 times
if necessary until the burner is lit. If the burner fails to
light, turn the control knob to the "off" position (O). Wait
5 minutes before repeating the operation.
5) As soon as the burner is lit, the other burner
automatically lights when the second control knob is
placed in the full flame ( ) position without pushing
the automatic igniter button again.
Important:
If the burner fails to light after the 2
nd
attempt, turn the
control knob to the "off" position (O) and check that the
burner oulets and venturi tubes are not blocked.
j) GRILL BURNER-MANUAL LIGHTING
If the automatic ignition should fail to operate, turn the
control knob to the "off" position (O).
Remove the cooking grate.
Light a match and bring it close to a burner, then push in
and turn the corresponding control knob anti-clockwise to
the Full Flow position ( ). Replace the cooking grate.
k) EXTINGUISHING THE GRILL
Return the control knobs to the "off" position (O), then
close the cylinder valve.
l) REPLACING THE GAS CYLINDER
- Always work in a well ventilated area and never in the
presence of a flame, spark or heat source.
- Return the control knobs in the "off" position (O) then
close the cylinder valve.
- Remove the regulator, check that the sealing joint is in
good condition.
- Put the full cylinder in place, refit the regulator, taking
care not to apply stress to the hose. Check for gas
leaks.