E - 1 - Igniting the appliance
Note: Gas opening and closing controls are located on
gas bottle and/or on pressure reducing valve.
Ignition spark, gas inlet control and temperature or
power controls are actuated from the control panel
located in the appliance top right section (fig. 1 item 1)
and (fig. 5 items A, B and C).
1- Open bottle cock and/or pressure reducing valve
handle and carry out a leak test.
2-a-Comfort Heat CR Version
- Do not place the heater just below an electric socket.
- Do not use the heater near a bath, shower or
swimming pool.
Set handle (A) to position ( ) and press the handle
for 10 seconds to allow the gas to reach the pilot
burner (fig. 5).
2-b-Comfort Heat CR Thermo Version
Set handle (C) to the maximum position and
press control button (
) for 10 seconds to allow
the gas to reach the pilot burner (fig. 5).
3- Push the flame ignition button (B) located next to
the (
) symbol) all the way down several times
while simultaneously holding down the handle
(A) or the control button (A) for 10 seconds. The
thermocouple is activated and the safety valve
does not cut off gas feed. Release button A or
handle A.
4- Check whether the appliance did light up. If not,
repeat the procedure from step 2).
5- The appliance must be held in maximum position
for about 10 minutes in order to fully activate the
catalytic panel.
Note: Some air may be trapped in the gas line. This
will prevent the appliance from lighting up during the
first attempt. In this case, it is necessary to repeat the
ignition procedure several times until the safety pilot
burner lights up.
During appliance operation, the safety pilot burner
must remain permanently lit in order to ensure correct
operation of the atmosphere analyser.
During the first setting to service, operate the appliance
at maximum power for at least 15 minutes in order
to eliminate the typical new appliance smell due to
the presence of protecting substances applied to the
component parts.
Ventilate the room during this operation.
E - 2 - Setting temperature or power (Fig. 5)
Your appliance is equipped with a setting handle which
makes it possible to adjust the temperature radiated
by the catalytic panel depending on the temperature
desired in the room.
a) Comfort Heat CR Version
Set the heating temperature by positioning handle index
between positions (
) and ( )(3: see fig. 5 -
Comfort Heat CR - item A)
b) Comfort Heat CR Thermo Version
To adjust heating temperature, position the adjustment
button(C)betweenthemaximum(▼)andminimum
levels (6 positions: see fig. 5 - Comfort Heat CR
Thermo - letter C).
E - 3 - Shutting down the appliance
Close bottle cock and/or gas pressure reducing valve
handle.
THIS APPLIANCE IS EQUIPPED WITH AN
ATMOSPHERE ANALYSER DEVICE WHICH
AUTOMATICALLY TURNS OFF THE APPLIANCE
SHOULD THE ROOM CONTAIN TOO HIGH A
CARBON DIOXIDE PERCENTAGE (CO
2).
IN THIS CASE, THOROUGHLY VENTILATE THE
ROOM, OTHERWISE THE APPLIANCE WILL NOT
RELIGHT.
F - REMOVING OR REPLACING THE GAS
BOTTLE
- Check that gas bottle cock and/or pressure reducing
valve handle is in the closed position.
- Open appliance rear plate (fig. 4 item B) and remove
the bottle from its housing, taking care not to pull or
bend the hose.
- Disconnect pressure reducing valve from gas bottle.
- Install the new gas bottle and carry out a leak test as
described under paragraphs D-1 and D-2.
G - STORAGE - SERVICING
1) Appliance
When it is not used, the appliance should remain open
and be stored in a dust-free place.
- Remove stains with soapy water, when the appliance
is cold. Wipe off with a cloth.
- Do not use abrasives which might damage the
paintwork.
- For heavy repairs, please call your vendor.
- The appliance must be periodically checked, more
particularly concerning condition of the connecting
hose.
2) Hose between the pressure reducing valve
and the appliance
- Periodically check hose for condition and replace it if it
displays ageing signs or cracks.
- The hose must be replaced by a new one of same
length and equivalent quality.
- The hose must be replaced in compliance with
the above-mentioned periodicity for the respective
countries.
- In France, if the expiry date printed on the hose is
reached, it must be replaced by a hose compliant with
the XP D 36-112 Standard.
- Comply with installation indications provided with these
new assemblies to be 0.50 m long, and with the
procedure described under paragraph C-2.
- If your appliance is to remain unused for a long period,
disconnect gas bottle.
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Campingaz Comfort Heat CR - CR 5000 Comfort wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info