662406
8
Zoom out
Zoom in
Vorherige Seite
1/56
Nächste Seite
8
2-a-IR 5000 Turbo Version
Plug in the appliance.
Caution: The appliance was designed to be supplied with
a 230 V 50 Hz voltage. Your installation must be equipped
with a grounding connection compliant with electrical
systems specifications in force.
- Do not place the heater just below an electric socket.
- Do not use the heater near a bath, shower or
swimming pool.
2-b-IR 5000 Version and IR 5000 Turbo Version
Set handle (A) to position (START) and press the
handle for 15 seconds to allow the gas to reach the
pilot burner (fig. 5).
2-c-IR 5000 Thermo Version
Set handle (C) to the maximum position (IIII) and press
control button (A) for 15 seconds to allow the gas to
reach the pilot burner (fig. 5).
3- Fully press several times the LH button marked with a
stylised lightning (
) (B) for lighting up the flame,
while holding handle (A) or control button (A) depressed
for 15 seconds. The thermocouple is activated and the
safety valve does not cut off gas feed.
Release button A or handle A.
4- Check whether the appliance did light up. If not, repeat
the procedure from step 2.
Note: Some air may be trapped in the gas line. This will
prevent the appliance from lighting up during the first
attempt. In this case, it is necessary to repeat the ignition
procedure several times until the safety pilot burner lights
up. During appliance operation, the safety pilot burner
must remain permanently lit in order to ensure correct
operation of the atmosphere analyser.
During the first setting to service, operate the appliance at
maximum power for at least 15 minutes in order to eliminate
the typical new appliance smell due to the presence of
protecting substances applied to the component parts.
Ventilate the room during this operation.
E - 2 - Setting temperature or power (FIG. 5):
Your appliance is equipped with a setting handle which
makes it possible to adjust the temperature radiated by
the infrared panel depending on the temperature desired
in the room.
a) IR 5000 Version and IR 5000 Turbo Version
- Set the heating temperature by positioning handle
index between positions (III) and (I) (3: see fig. 5 - IR
5000 - item A
and - IR 5000 Turbo - reference A)
b) Exclusive to IR 5000 Turbo Version
After lighting up your appliance in compliance with
the indications of paragraph E-1, you can increase its
heating performance by means of the ''Turbo" function.
The "Turbo" function provides for fast and even heating
of the room because it uses a tangential ventilation to
propel the hot air now out of the appliance.
The "Turbo" function is turned on / off by pressing the
red button (fig. 5 - IR 5000 Turbo - item C).
CAUTION:
The appliance was designed to be supplied with a
230 V 50 Hz voltage.
Your installation must be equipped with a grounding
connection compliant with electrical systems
specifications in force.
c) IR 5000 Thermo Version
- Set the heating temperature by positioning handle
index between positions maximum (IIII) and
minimum (I) (see fig. 5 - IR 5000 Thermo - item C)
- Open appliance rear plate (fig. 1 item 3).
Note: If the appliance is new, remove the plastic cable
tie (Figure 1 number 4), lift and remove rear plate (3).
D - 1 - Installing gas bottle:
- Position the gas bottle on the floor behind the appliance.
- Check whether bottle cock and/or pressure reducing
valve handle is in “closed” position.
- Screw in or engage pressure reducing valve to gas
bottle or gas bottle cock (fig. 3 item B).
- Install gas bottle through appliance rear so that the
hose does not touch appliance metal panels and is not
excessively bent or pinched.
- Check that the hose runs normally and is neither bent
nor pulled.
- Install appliance rear plate (fig. 4 item A).
D - 2 - Tightness:
In case of leak, appliance gas supply must be shut
down using gas bottle cock and/or pressure reducing
valve handle.
Do not carry out leak tests with a flame, use a gas leak
detecting liquid.
- Apply gas leak detecting liquid to bottle/pressure
reducing valve/hose/appliance unions.
- Open the gas inlet (bottle cock and/or pressure reducing
valve handle) (fig. 4).
- If bubbles appear, this means that there are gas leaks.
- To remove the leak, tighten hose nuts and/or hose
clamps if any. If a part is defective, have it replaced.
The appliance should not be returned to service until the
leak is removed.
- Close gas bottle cock.
Important: In case of gas leak or odour, immediately
close bottle cock and/or pressure reducing valve
handle. Enhance room ventilation by opening the
windows. Ask a specialised technician to check the
appliance and proper bottle connection.
A leak test should be carried out at least once a year and
whenever the gas bottle is changed.
E - UTILISATION
OPERATING PRECAUTIONS:
DO NOT install the appliance next to a wall, curtains
or a sofa or armchair.
DO NOT cover the appliance with clothes or other
objects.
DO NOT move the appliance when in operation.
The appliance must ALWAYS be directed to the
centre of the room.
The appliance must be put in a dry place.
This appliance protecting grid is designed to
prevent fire hazards or burns and no part shall be
permanently removed.
THE GRID DOES NOT TOTALLY PROTECT YOUNG
CHILDREN OR THE DISABLED.
E - 1 - IGNITING THE APPLIANCE:
Note: Gas opening and closing controls are located on
gas bottle and/or on pressure reducing valve.
The ignition spark, gas inlet control and power control are
operated on the control panel located in the top right-hand
corner of the appliance. (fig. 1 item 1) and (fig. 5 items A,
B and C)
1- Open bottle cock and/or pressure reducing valve
handle and carry out a leak test.
GB
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Campingaz IR 5000 THERMO wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info