802432
7
Zoom out
Zoom in
Vorherige Seite
1/132
Nächste Seite
7
Reason: The device is not placed on a flat surface. So, put the device on a flat and hard place to reduce noise.
Reason 4: Air-inlet or air out-let is blocked. So, remove blockage.
If nylon filter (12) is clogged with dust, then the effectiveness of the device is reduced, be sure to clean the filter once every two weeks.
Reason 2: Door and windows are open , many heat sources in the room. So, close the door and windows, move out heat sources.
Problem II.: The device auto-restarts frequently.
TROUBLESHOOTING
Reason1: Direct sunlight. So, drawn the curtains.
1.Pull out drainage plug (8) to flow out water.
- Force down from the outside the latch of filter frame (11) with hands and pull out to yourself to remove the filter frame(11).
4.Clean and dry filters, then reinstall them.
Storage the device and all device components in dry place.
Problem I.: The air conditioning does not work.
3.Turn off the device and pull out plug .
Reason 2: The water full indicator light “N” is illuminated. So, discharge the water.
Reason 1:There is no electricity. So, turn it on after connecting it to a socket with electricity.
Reason 3: Filters are too dirty. So, clean or replace filters.
Problem III.: Big Noise
Reason: Compressor time-delay protection turn on. So, wait for 3 minutes until the temperature is lowered, and then restart the device.
- Put nylon filter (11) into warm water with neutral detergent (about 40 / 104) and dry it in the shade after rinsing clean.
Problem IV.: Compressor does not work.
- Clean the upper and down filters frame (11) after remove both nylon filters (12) from the filter frame(11). – picture G.
If the device will be unused for a long time, please do as following :
6.Put the device into plastic bag , and place it on a dry place.
STORAGE
5.Pull out exhaust pipe for safe keeping .
2.Let the device runs under fan mode for 2 hours to dry out the device's internal.
7.Remove batteries of the remote control and keep them properly.
1.Compressor protection: Three minutes later after power on / restart, compressor starts to run.
Button "G" - press it to set up or cancel timer.
4. During drainage, the body can be tilted slightly backwards.
Button "F" - press it to select fan speed in sequence: slow / fast wind speed.
Clean with surface of device with a wet soft cloth. Don't use chemicals, such as benzene, alcohol, gasoline, otherwise, the surface of the
device will be damaged or even the whole device will be damaged.
b) Net nylon filters cleaning
Button "E" - press it to set up or cancel sleep mode.
a) Housing cleaning
This device is equipped in auto-water-evaporating system. Condensed water cycle will cool down the condenser, which will not only
improve cooling efficiency, but also save energy.
2. Power off the device.
3. Prepare flat container (not included to set) to drain the water. Locate it under the drain hole (8)
3. Remove the rubber cap from the drain hole (8) – picture F.
1. If inner water tank is full, the water full indicator lamp “N” will be illuminated, the device enter into standby mode, buzzer shouts,
compressor stops and all buttons is invalid till the device recovers to be normal, after water drainage.
5. After water stops to pouring out, close the rubber cap (8).
6. Restart the device, the device will runs normally.
Button “H” - press to set up or cancel automatic air oscillation function.
CLEANING & MAINTENANCE
switched on.
Cleaning: before cleaning and maintenance, turn off the device and unplug the plug.
2.Overflow protection function: when the water full indicator lamp “N” will be illuminated and the buzzer will alarm for several second, the
device turn off automatically. In this case, you need to drainage the water (details see Drainage Instructions at the end of this chapter). After
the water is emptied, the device will get into standby status.
PROTECTION DEVICES
3. Frost Protection Function: In cooling mode, if the temperature of the EVA pipe sensor is too low, the device will automatically enter
protection status. When the temperature of the EVA pipe sensor rises to a certain temperature, it can automatically revert to normal
operation.
DRAINAGE INSTRUCTIONS:
Note: when abnormal situations are occurred, turn off device and pull out plug, then contact with professional service for help .
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Camry CR 7929 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info