764890
7
Zoom out
Zoom in
Vorherige Seite
1/9
Nächste Seite
GRAND RAPIDS SPA
PART 7: DRAIN & STORE
Drain System
Locate and remove the external threaded Drain Cap. Attach Drain Hose to Drain Outlet. Locate and remove
the stopper on the spa oor to allow water to drain.
Dry the Spa and Portable Control Unit
After an RCD test, press ‘JETS’ to blow out the water inside the jet holes. Turn PCU off and disconnect all connectors
from connection ports on the PCU. Turn PCU back on and run blower for 30 seconds to allow excess water to clear
from blower port. Unplug RCD and hold PCU at an angle, allowing water to drain from connection ports. Once water
ow stops, remove Filter Housing Lid and hold PCU upside down. Give the PCU a slight shake, allowing all excess
water to be removed. Close Filter Housing Lid when complete. NOTE: PCU must be stored upright. Leaving PCU at
an angle or upside down may result in damage. Operate with the jets pipe connected, press jets to force excess
water out from spa body/bladder, then dry down, store in a warm & dry place.
Storage
Use a towel to wipe off the spa and dry for 24 hours. Unscrew the Air Valve on the lid. Deate the spa lid, then
deate the spa and gently fold them for storage. It is recommended that you store the spa in its original package in
a warm dry place.
PART 8:
SPA OPERATION CHECK LIST
CHECK 1: Water Level
Ensure water is high enough and level in the
spa. Check if this will help the spa
performance.
CHECK 2: Inside Connection
Caps
Make sure the clear plastic Inlet/Outlet caps have
been removed before turning on the PCU.
CHECK 3: Bleed Air out of
Portable Control Unit
If PCU makes a grinding noise, there is a
restriction of water ow to the PCU. Bleed
the air out of the pump by unscrewing the
Air Valve. Check if this resolves the pump’s
malfunctioning.
CHECK 4: Back Flush PCU
Back ushing the PCU is recommended every
few months to help PCU performance and
longevity. Simply remove the PCU from the tub
connections (cap ports inside tub rst if you do
not want to drain spa) remove the lter and run
water from a garden hose into the ‘Heater Port’.
Flush for 1to 2 minutes and hold PCU
upside down to drain remaining water.
PART 9:
CONTROL UNIT MESSAGES
CODE Causes Solutions
E1/ E2 Temperature control
sensor short circuit
or open circuit
1. Unplug RCD from outlet
2. Please contact for service
E3 High Heat:
The water is
over 113°F(45°C)
1. Unplug the RCD cable from the outlet
2. See Part 8: Spa Operation Check List for possible solutions
3. Power on spa again to see if error is resolved, if not please
contact for service Note: lling with hot tap water upon initial ll
may cause this error.
Drain and rell with cold water
E4 Freezing Conditions
Detected: The water is
lower than 36°F(2°C)
1. Unplug the RCD cable from the outlet
2. See Part 8: Spa Operation Check List for possible solutions
3. Power on spa again to see if error is resolved, if not please
contact for service
E5 Overheat:
The water is
over 122°F(50°C)
1. Unplug the RCD cable from the outlet
2. See Part 8: Spa Operation Check List for possible solutions
3. Power on spa again to see if error is resolved, if not please
contact for service. Note: lling with hot tap water upon initial ll
may cause this error.
Drain and rell with cold water
E6 Inlet or outlet on inner
wall is blocked
See Part 8: Spa Operation Check List for possible solutions,
otherwise contact for service. Hold down ‘HEAT’ for 5 seconds
E7 Low Flow
1. Filter cartridge is dirty
2. Spa water does not
reach minimum water level
3. Air-lock in pump
See Part 8: Spa Operation Check List for possible solutions,
otherwise contact for service
CHG
FIL
Automatic timed
reminder
to check lters
Hold down ‘HEAT’ for 5 seconds to clear message
FIL Spa is in Filtration mode No action necessary will go back to temp after 30 seconds
L-1 1st massage speed Gentle therapeutic massage
L-2 2nd massage speed Normal therapeutic massage
(12) (13)
GRAND RAPIDS SPA
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Canadian Spa Company Grand Rapids 2021 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info