764888
12
Zoom out
Zoom in
Vorherige Seite
1/32
Nächste Seite
Owners Manual
12
Installation: Electrical requirements
ELECTRICAL REQUIREMENTS FOR SWIM SPA (EUROPE)
Your swim spa runs on 230V 50Hz single phase. There are two
configurations you can run your swim spa on.
The minimum supply current is 50 amps, in this configuration the
heater will disengage if all 4 pumps are turned on.
The second option is to have the heater on even when the spa is
running at full speed; in very cold climates this may be desirable
especially if using the spa outdoors in winter continually. In this
configuration a 60 amp supply is required.
The size of the wire required will be determined by the distance to
the supply and the shielding method; your electrician will be able to
advise you of the required wiring for your specific situation.
Access
The Swim spa will arrive assembled as a single unit on a pallet. It will
weigh approx one metric ton and cannot be disassembled. For this
reason you will need to have a crane or other mechanical method of
unloading the spa and getting it to your chosen site.
We recommend you book a contract lift where the lifting company
will assess the situation and method of lift and carry insurance in
case of accidental damage to the spa or the property. The spa
warranty does not cover damage from installation. It is the
responsibility of the customer or his agents be it crane company or
lift operator to assess the lift and control all aspects of the moving
of the spa. Canadian Spa Company will not take responsibility for
any part of the moving of the spa, and cannot advise on the methods
used to move the spa.
Base
The base for your swim spa must be a flat level surface that contacts
the entire base of the spa. We recommend 15 cm of re-enforced
concrete but any flat level base that is stable and will not shift or
settle will suffice. If sinking your spa into the ground you need to
provide adequate drainage for water so that the hole the spa sits in
cannot flood as this will damage the electronics and electrical
components. Also at least a metre of access to the entire front of the
spa filters is required for component access. You are responsible for
providing adequate access in order to repair the spa in case of fault.
CIRCUIT BOARD CODES:
E = 1 x Earth Screw
S = 7 x Standard Screws
H1 = Heater Connection ‘1’
H2 = Heater Connection ‘2’
SA = Sensor Port ‘A
SB = Sensor Port ‘B’
T-Pad 1/2/3 = Topside Ports 1, 2 & 3
(Molex Connector)
JUMPER:
J8 = Jumper on 1 pin when using 2kW
or 1kW Heater. Jumper on 2 pin when
using 3kW Heater
J91 = Jumper on 1 pin enables Real
Time Clock function (ML900), Jumper
on 2 pin disables RTC function
1-Spd P2
Blank
Mp3
2-Spd P1
Not Used Ozone
Light
T-pad 1 T-pad 2T-pad 3
H1
H2
30
E
S
S
SS
S
S
S
3a Light Fuse
30a Pump 1 Fuse
2a Mp3 Fuse
10a Blower Fuse
30a Pump 2 Fuse
SA SB
J91
J8
J59
J36
J58
55596 c/board
NanswGL2km3 Circuit Board (Swim spa models: St Lawrence 13’ and 16’ Swim Spa)
Expander Board - 55026: for pump 3
&4 (split plug)
Pump 3 & 4
30 A Pump fuse
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Canadian Spa Company Montreal wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Canadian Spa Company Montreal

Canadian Spa Company Montreal Bedienungsanleitung - Deutsch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info