Meaning:
No message on display.
Power has been cut off to the spa.
Temperature unknown.
“Overheat” - The spa has shut down. One of the
sensors has detected 118°F/48°C at the heater.
“Overheat” - The spa has shut down. One of
the sensors has detected that the spa water is
110°F/43°C.
“Ice” - Potential freeze condition detected.
Spa is shut down. The sensor that is plugged
into the Sensor “A jack is not working.
Spa is shut down. The sensor that is plugged
into the Sensor “B” jack is not working.
Sensors are out of balance. If alternating with
spa temperature, it may just be a temporary
condition. If ashing by itself, spa is shut down.
A signicant difference between temperature
sensors has been detected. This could indicate a
ow problem.
Persistent low ow problems. (Displays on the
fth occurrence of HL message within 24
hours.) Heater is shut down, but other spa
functions continue to run normally.
Possible inadequate water, poor ow, or air
bubbles in detected in the heater. Spa is shut
down for 15 minutes.
Inadequate water detected in heater. (Displays
on third occurrence of dr message.) Spa is
shut down.
Action Required:
The control panel will be disabled until power returns. Spa
settings will be preserved until next power up.
After the pump has been running for 2 minutes, the
temperature will be displayed.
DO NOT ENTER THE WATER. Remove the spa cover and allow
water to cool. Once the heater has cooled, reset by pushing
any button. If spa does not reset, shut off the power to the spa
and call your dealer or service organization.
DO NOT ENTER THE WATER. Remove the spa cover and allow
water to cool. At 107°F/42°C, the spa should automatically
reset. If spa does not reset, shut off the power to the spa and
call your dealer or service organization.
No action required. The pump and blower will automatically
activate regardless of spa status.
If the problem persists, contact your dealer or service
organisation. (May appear temporarily in an overheat situation
and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat situation
and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organisation.
Check water level in spa. Rell if necessary. If the water level
is okay, make sure the pumps have been primed. If problem
persists, contact your dealer or service organization.
Follow action required for HL message. Heating capability of
the spa will not reset automatically; you may press any button
to reset.
Check water level in spa. Rell if necessary. If water level is
okay, make sure the pumps have been primed. Press any
button to reset, or this message will automatically reset within
15 minutes. If problem persists, contact your dealer or service
organisation.
Follow action required for dr message. Spa will not
automatically reset. Press any button to reset.
Message
--
HH
OH
IC
SA
Sb
Sn
HL
LF
dr
dy
(9)
Diagnostic Messages
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Canadian Spa Company Muskoka wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info