V. INSTALLATION
A. Outline
This printer is packaged and shipped from the factory after careful adjustments and rigorous
inspections.
When installing the printer, it is important to demonstrate its performance in the same way
as when it passed the factory inspection.
The service engineer must sufficiently understand the performance of the printer, install it
correctly in a location with an appropriate environment, and conduct sufficient checks of the
unit.
B. Location Selection
Before taking the printer to the customer’s premises, you should confirm the following installa-
tion conditions.
1. Power supply
Use the following power supplies:
• Line voltage (AC): -10%, +6% rated voltage
• Power frequency: 50/60 Hz±2 Hz
2. Operating environment
Install in a location that meets the following conditions:
• Level, flat surface
• Temperature, humidity within the following ranges:
Surrounding temperature: 7.5 ~ 32.5°C
Surrounding humidity: 5 ~ 90%RH (relative humidity)
• Cool, well-ventilated space
Do not install in the following locations:
• Exposed to direct sunlight
If you cannot avoid such a location, hang heavy curtains, etc. to shut out the direct sunlight.
• Near magnets and devices that emit a magnetic field
• Areas with vibration
• Dusty places
• Near fire or water
3. Installation space
Install the printer at a suitable distance from the walls, leaving enough room to operate it (see
Figure 1-5-1).
When installing the printer on a desk, be sure that it is large enough to accommodate the
printer’s feet (rubber pads) and strong enough to stand its weight.
1 - 12