To achieve a high degree of dust extraction, use a dust
category M vacuum cleaner for mineral dust together
with this power tool.
Provide good ventilation of the working place.
It is recommended to wear a FFP2 lter class respirator.
Observe the relevant regulations in your country for the
materials to be worked.
Please observe the following notes in order to reduce the
dust emissions occurring while working.
Only use combinations of diamond grinding wheels, con-
crete grinders with mounted guard and extraction hood
as well as dust category M vacuum cleaners that are re-
commended by Carat. Other combinations can lead to
insu󰀩cient dust collection and separation.
Observe the operating instructions of the vacuum clea-
ner for maintenance and cleaning of the vacuum cleaner,
including the lter. Empty dust collection containers im-
mediately once full. Clean the lters of the vacuum clea-
ner regularly and always insert the lters completely into
the vacuum cleaner.
Only use vacuum hoses as intended by Carat. Do not
manipulate the vacuum hose. When rocks or chunks of
stone/masonry are drawn into the vacuum hose, cease
work and clean the vacuum hose immediately. Prevent
the vacuum hose from being bent or creased.
Use the concrete grinder only as intended for.
Only use tools that are in perfect condition. Decrease in
work progress is noticeable whilst using worn tools.
Observe the general requirements for construction sites.
Provide for good ventilation.
Ensure that the work area is free of obstructions. For lon-
ger grinding jobs, the vacuum cleaner must be able to
move along freely and at the right time.
Wear hearing protection, protective goggles, a dust
mask and gloves as required. As dust mask, use at least
a particle-ltering class FFP 2 half-mask.
Use a suitable vacuum cleaner for cleaning the work-
place. Prevent settled dust from being swirled up by
sweeping.
ASSEMBLY INSTRUCTIONS
Pull the mains plug of the power tool from the
socket, before any work on the machine itself!
It’s recommended to wear worker’s gloves while
assembling or changing the diamond grinding wheels.
Diamond grinding wheels become very hot due operating.
Don’t touch them until they have cooled down.
Diamond grinding wheels
This power tool is not intended to be used in combination
with other tools than diamond grinding wheels. The guard
doesn’t supply suitable protection for tools other than dia-
mond grinding wheels.
The arbor of the diamond grinding wheels must t the
mounting ange. Do not increase the arbor of the diamond
grinding wheels. Do not use reducers or adapters.
The permissible speed (rpm) of the diamond grinding
wheels used must be at least the 10.200 min-1.
Due to continuous product development and technical
improvements, technical information may be changed
without prior notice.
PERSONAL SAFETY
Read all operating and safety instructions be-
fore using the machine. Follow the instructions
strictly for your own safety.
MACHINE DATA
Type SL-1253N
Rated power input 1700W
Protection class 2 / II
No-load speed 10.200 min-1
Width across ats clamping bolt 13 mm
Arbor diameter Ø 22,2 mm (7/8”)
Ø Diamond grinding wheels Ø 125 mm
Slot depth 0 – 27 mm
Slot width 10 – 40 mm
Weight 4,5 kg
MAIN PARTS
The main parts are numbered identical to the graphic of
the power tool at page 3 of this manual.
1. Guard and extraction hood
2. Cover
3. Inner guard
4. Vacuum hose
5. Vacuum connection
6. Auxiliary handle
7. ON/OFF-switch
8. Spindle lock button (won’t be used)
9. Mounting ange
10. Diamond grinding wheels
11. Spacers
12. Locking ange
13. Clamping bolt
14. Depth locking
15. Wedge
16. Wrench for locking bolt
17. Two-pin spanner for clamping nut
INTENDED USE
The machine is intended to grind slots, in conjunction with
a dust-category M vacuum cleaner, in mineral materials
such as reinforced concrete, brickwork and road surfaces,
without the use of water.
POWER SUPPLY
The tool should be connected only to a power supply of the
same voltage as indicated on the nameplate, and can only
be operated on single-phase AC supply. The tool is double-
insulated in accordance with European Standard and can
therefore be used from non-grounded sockets.
DUST EXTRACTION
Dust released when processing (grinding of
minerals) can be harmful to one’s health. Tou-
ching or breathing-in the dusts can cause al-
lergic reactions and/or lead to respiratory infec-
tions of the user or bystanders.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Carat SL-1253N DUSTEC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info