586704
5
Zoom out
Zoom in
Vorherige Seite
1/7
Nächste Seite
USER’S GUIDE 2412
5
COM
1
:
58
INFRA RED
INFRA RED
After about
one second
COM.MENU
WatchPC
Other (PDA, etc.)
Portable game device
COM.MENU
SEND
RECEIVE
IR Mode
Use the IR Mode to exchange data between two watches or between your
watch and computer, or some other device.
The following shows compatibility of data communication between this watch
and other CASIO Wrist Camera Models.
Note
An infrared adapter or an IR port is required to exchange data with this watch.
The following procedure covers data communication between two watches
only. See the CD-ROM that comes with the watch and the documentation that
comes with the infrared adapter for information about data communication with
a computer.
Exchanging Data Between Two Watches
To exchange data between two watches, orient the watches as shown above.
The 10cm (4 inches) and 30-degree maximums shown in the above
illustration apply only when the watches are pointed straight at each other.
The maximum allowable distance may be less if either watch is at an angle
(not pointed straight).
At an angle of 15 degrees or more, you may need to move the two watches
very close to each other.
To enter the IR Mode
In the Timekeeping Mode, press D twice to enter the IR Mode.
An initial screen appears for about one second, followed by the
COM. MENU screen.
To send an image
1.On the COM. MENU screen, use B or E to
select watch ( ).
2. Press F to display the watch-to-watch send
menu.
3. Press C to display the image selection screen.
Each press of C toggles between the image and
the send menu.
The watch automatically returns to the send
menu if you leave an image on the display for
about five seconds.
10cm (4 inches) maximum
15 degree maximum
SEND
2‰‰1. 6.3‰.P1‰:58
Wrist Camera Model
WQV-3 series (Module 2411)
WQV-1/WQV-2 series
(Module 2220)
Communication with this watch
Supported
Not supported (different protocol)
4.Use E(+) and B (–) to scroll through the images
and display the one you want to send.
SEND is displayed in the upper left corner of the
image screen.
You can send only one image at a time between
watches.
5.Align the IR ports of the two watches with each
other.
Put the receiving watch into receive standby at
this time. See “To receive an image” for more
information.
SEND
OK
SEND
6.On the sending watch, press F to send the
displayed image.
The data send screen shown nearby appears
while an image send operation is in progress.
The message OK appears momentarily after the
image send operation is complete. Next, the
watch returns to the send menu.
Pressing A during the above procedure displays
the COM. MENU screen.
After you are finished sending images, press D
to return to the Timekeeping Mode.
To receive an image
1.On the COM. MENU screen, use B or E to
select watch ( ).
2.Press F to display the watch-to-watch send
menu.
3.Press E to display the watch-to-watch receive
menu.
Pressing B returns to the watch-to-watch send
menu.
4.Press F to enter receive standby.
5.Align the IR ports of the two watches with each
other, and perform the send operation on the
sending watch.
See “To send an image” for more information.
The message OK appears momentarily, followed
by the received image. Next, the watch returns to
the receive menu.
Pressing A during the above procedure displays
the COM. MENU screen.
After you are finished receiving images, press D
to return to the Timekeeping Mode.
SEND
RECEIVE
Communication Errors
Screen messages appear in the IR Mode to let you know when there is a
problem with data communication. When this happens, check the following to
find out what you need to do. Also, you can avoid data communication
problems by carefully observing the advice under “Communication
Precautions”.
Communication Screen Messages
Other Messages
Communication Precautions
The two IR ports must be within 10cm (4 inches) and 30 degrees of each
other.
Proper data communication may also be impossible if the two IR ports are
too close to each other.
At an angle of 15 degrees or more, you may need to move the two IR ports
very close to each other.
Do not move the watch while communication is in progress.
Make sure there is nothing between the two IR ports that blocks the path of
the IR signal.
Infrared communication may not be possible in areas where lighting is bright,
near a window, etc.
In the case of inverter fluorescent lighting or other very strong light, try
turning off the light or move to an area where light is not shining directly onto
the infrared ports.
An unrelated nearby IR data communication operation can interfere with
proper IR data communication.
The maximum allowable distance between the IR ports may be less than
10cm when watch battery power is low.
The watch automatically returns to the COM. MENU screen about five
minutes after the image selection screen or receive standby screen is
displayed. If the point where five minutes elapse occurs while a data send/
receive operation is in progress, the operation continues until it is complete,
after which the watch automatically returns to the COM. MENU screen.
ERROR SEND
(Sender),
ERROR RECEIVE
(Receiver)
MEMORY FULL
Data send or receive failed for some reason.
Tr y again.
Memory of the receiver is full. Delete data you
no longer need and try again.
Something is interfering with proper data
communication. Correct the cause of the
problem. If data communication is not restored
within about 25 seconds, ERROR appears on
the display.
SEND
RECEIVE
(Receiver)
(Sender)
CHECKING DATA
REC ERROR
This message appears when an image is being
processed after data is received.
Data cannot be saved because some problem
occurred while accessing flash memory.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Casio 2412 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Casio 2412

Casio 2412 Bedienungsanleitung - Deutsch - 27 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info