E-48
Pressure Sensor and Temperature Sensor Calibration
The pressure sensor and temperature sensor built into the watch are calibrated at the factory and normally
require no further adjustment. If you notice serious errors in the pressure readings and temperature
readings produced by the watch, you can calibrate the sensor to correct the errors.
Important!
• Incorrectly calibrating the barometric pressure sensor can result in incorrect readings. Before
performing the calibration procedure, compare the readings produced by the watch with those of
another reliable and accurate barometer.
• Incorrectly calibrating the temperature sensor can result in incorrect readings.
Carefully read the following before doing anything.
–
Compare the readings produced by the watch with those of another reliable and accurate thermometer.
– If adjustment is required, remove the watch from your wrist and wait for 20 or 30 minutes to give the
temperature of the watch time to stabilize.
E-49
To calibrate the pressure sensor and the temperature sensor
1. Take a reading with another measurement device to determine the
exact current barometric pressure or temperature.
2. With the watch in the Timekeeping Mode or in any of the sensor
modes, press
B
to enter the Barometer/Thermometer Mode.
3. Hold down
E
for at least two seconds.
SET Hold
will fl ash on the
display and then
TEMP
will appear in the upper display. Keep
E
depressed until
TEMP
appears.
• The c urre nt temp erat ure cal ibrat ion s et ting w ill fl as h in the l ower
disp lay at thi s tim e.
4. Press
D
to move the fl ashing between the temperature value and
barometric pressure value, to select the one you want to calibrate.
5. Use
A
(+) and
C
(
–
) to select the temperature and barometric
pressure value display units as shown below.
Temperature 0.1°C (0.2°F)
Barometric Pressure 1 hPa (0.05 inHg)
• T o retu rn the c urre ntly fl as hing va lue to i ts ini tial fa ctor y de fault
setting, press
A
and
C
at the s am e tim e. OFF will appear at
the fl ashing l oc atio n for a bou t one s ec ond, fo llo wed by th e init ial
default value.
6. Press
E
to return to the Barometer/Thermometer Mode screen.
E-50
Barometer and Thermometer Precautions
• The pressure sensor built into this watch measures changes in air pressure, which you can then apply
to your own weather predictions. It is not intended for use as a precision instrument in offi cial weather
prediction or reporting applications.
• Sudden temperature changes can affect pressure sensor readings. Because of this, there may be
some error in the readings produced by the watch.
• Temperature reading are affected by your body temperature, direct sunlight, and moisture. To achieve
a more accurate temperature reading, remove the watch from your wrist, place it in a well ventilated
location out of direct sunlight, and wipe all moisture from the case. It takes approximately 20 to 30
minutes for the case of the watch to reach the surrounding temperature.
E-51
Using the Altimeter Mode
The watch takes altitude readings and displays results based on air pressure measurements taken by a
built-in pressure sensor. It also saves various types of altitude records and data.
Getting Ready
Before actually taking an altitude reading you need to select an altitude screen format and select an
altitude reading interval.
Selecting the Altitude Screen Format
You can select either of two screen formats for the Altimeter Mode.
Screen 1
Altitude
Tendency Graph
Altitude
Current time
Screen 2
Relative altitude
Altitude
Current time
• Altitude tendency graph contents are updated each time you take an altitude reading.
• To take readings of the difference between the altitude at your current location and the altitude at a
reference point, select Screen 2. See “Using an Altitude Differential Value” (page E-56) for more
information.
E-52
To select the altitude screen format
1. In the Altimeter Mode, hold down
E
for at least two seconds.
• SET Hold w ill fl as h on th e disp lay and t hen ALTI will appear in the upper displa y . Keep
E
depressed until AL T I appears.
• The c urre nt alt itud e valu e will a ppea r at thi s tim e.
2. Press
D
twice.
• DISP will appe ar, and the n the c urren t scre en set ti ng wil l appe ar in t he upp er dis play.
3. Use
A
to toggle the setting between the two screens.
Screen 1 Screen 2
4. Press
E
to exit the setting screen.
E-53
Selecting the Altitude Auto Reading Interval
You can select either of the following two altitude auto reading interval.
0’05
: Readings at one-second intervals for the fi rst three minutes, and then every fi ve seconds for
approximately the next hour
2’00
: Readings at one-second intervals for the fi rst three minutes, and then every two minutes for
approximately the next 12 hours
Note
• If you d o not p er for m any bu tto n ope rati on wh ile in t he Al tim eter M ode, t he watch w ill retu rn to th e
Tim eke epin g Mo de auto mat ica lly af ter 12 ho urs (alti tud e auto re ading i nter val: 2’0 0 ) or afte r on e
hou r (altitu de auto re adin g inter val: 0’0 5).
• If tre k log o pera tio n is in pro gres s wit h 0’05 sele cted as t he al tit ude au to mea sure men t meth od,
exiti ng th e Alt ime ter Mo de to a noth er m ode wi ll auto mat ica lly ca use t he auto re adin g inter val t o
change to 2’00.
To select the altitude auto reading interval
1. In the Altimeter Mode, hold down
E
for at least two seconds.
SET
Hold
will fl ash on the display and then
ALTI
will appear in the upper
display. Keep
E
depressed until
ALTI
appears.
• The c urre nt alt itud e readi ng valu e will a ppe ar at th is tim e.
2. Press
D
to display the current altitude auto reading interval setting.
• This will cause INTER VAL to s croll a cross t he top d isplay. The
curre nt alt itud e auto re ading i nter val s ett ing (0’0 5 or 2’00) will b e
fl ashi ng in th e cen ter dis play.
3. Press
A
to toggle the altitude auto measurement interval setting
between
0’05
and
2’00
.
4. Press
E
to exit the setting screen.
E-54
Taking Altitude Readings
Use the procedure below to take basic altitude readings.
• See “Using Reference Altitude Values” (page E-58) for information about how to make altimeter
readings more accurate.
• See “How does the altimeter work?” (page E-65) for information about how the watch measures altitude.
E-55
To take altitude readings
1. Make sure the watch is in the Timekeeping Mode or any one of the
sensor modes.
• The s ens or m odes a re: Digi tal C om pass M od e, Baro mete r/
The rm ome ter Mo de, an d Alt ime ter Mo de.
2. Press
A
to start auto altimeter readings.
• The c urre nt alt itud e valu e is disp layed in u nits o f 1 mete r (5 feet).
• For i nfor mat ion a bou t the m eas urem ent in ter val, se e page E - 53 .
Note
• After you are fi nished, press
D
to return to the Timekeeping Mode and
stop auto altimeter readings.
• The watch will return to the Timekeeping Mode automatically if you do
not perform any operation (page E-18).
• The measurement range for altitude is –700 to 10,000 meters (–2,300
to 32,800 feet).
• The displayed altitude value changes to
- - - -
if an altitude reading
falls outside the measurement range. An altitude value will reappear as
soon as the altitude reading is within the allowable range.
• Normally, displayed altitude values are based on the watch’s preset
conversion values. You also can specify a reference altitude value, if
you want. See “Using Reference Altitude Values” (page E-58).
• You can change the unit for displayed altitude values to either meters
(m) or feet (ft). See “To specify temperature, barometric pressure, and
altitude display units” (page E-40).
Screen 1 Selected
Altitude Tendency Graph
Altitude
Current time
Screen 1 Selected
Altitude Tendency Graph
Altitude
Current time
Screen 2 Selected
Relative altitude
Altitude
Current time
Screen 2 Selected
Relative altitude
Altitude
Current time
Operation Guide 3415