The pressure history bar displays the moving atmospheric pressure history of the past 12 hours
which allows for forecasting. To view air pressure history for the past 12 hours, press the “hist”
button to select and view how many hours (repeatedly press the “hist” button).
The respective values can only be available after the barometer recorded the pressure date in the
past 12 hours. The spectrum bar chart indicates pressure changes of the past 1, 2, 3, 6, and 12
hours and is shown for a range of -0.24 to +0.24 in/Hg and -8 to +8 mb/hPa.
y Temperature & Humidity Alert – press the “alert” button on the rear of the Receiver to turn
the alert on or off. Press and hold the “alert” button to enter the setup mode. The indoor and
outdoor temperature and humidity upper and lower limits can be set by using the “+” and “-”
buttons and pressing “alert” to confirm each setting. When either the temperature or humidity
alert values have been reached while the alert is activated, the respective values will flash and
the alarm will sound --press “alert” to stop the alarm.
y Alarm Setting – Press the “alarm” button to toggle between alarm 1 and alarm 2, and normal
time. In “alarm 1” or “alarm 2” press and hold to set the alarm time by using the “+” and “-”
buttons to set the hour and minute and press the “alarm” button to confirm each. To turn either
alarm on or off, toggle the “+” button and you will see a bell icon for alarm 1 or alarm 2 or both
or none.
y Snooze/Light – when the alarm goes off, press the “snooze” button to go into snooze mode and
the alarm will go off again after 9 minutes and then continue to do this every 9 minutes. To stop
the snooze, press the “alarm” button. To enable the backlight for a moment just push the
“snooze/light” button in normal mode and for having the light on for a longer time keep holding
down the button.
y Channel – if your Sensor is set correctly to Channel 1, then a small icon to the left of outdoor
temperature display will show a “1” in a box. If you do not have an outdoor temperature and
humidity display, make sure that the “1” is displayed and if not (shows a 2 or 3), then push the
“CH” button until it shows the “1”.
Specifications:
y Indoor Temperature Range = 0º to +50º C (+ 32º to + 122º F)
y Remote Sensor Temperature Range = -20º to + 60º C (-4º to + 140º F)
y Indoor/Outdoor Humidity Range = 20% to 95% Relative Humidity
y Resolution = ± .5º C (± 1.5º F) for temperature & ± 1.5% humidity
y Altimeter = 328 ft to 8202 ft (100 m to 2500 m)
y Barometer = 26.80 to 31.01 in/Hg (900 to 1050 mb/hPa)
y Clock = digital quartz
y Transmission = RF433 MHz
y Dimensions = Receiver – 4.0” x 1.0” x 10.0” (102mmx25mmx254mm) Sensor - 2.5” x 1.0” x
3.6” (63mm x 25mm x 91 mm)
y Weight = Receiver - 14oz/397g Sensor - 3oz/85g
2835 Columbia St.
Torrance, California 90503 U.S.A.
www.celestron.com
Printed in China 0110 RoHS
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Celestron 47005 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info