by inputting a value which quickly rewinds the motors just enough to eliminate the play between gears. The amount of
compensation needed depends on the slewing rate selected; the slower the slewing rate the longer it will take for the star to
appear to move in the eyepiece. There are two values for each axis, positive and negative:
Positive is the amount of compensation applied when you press the button, in order to get the gears moving quickly without a
long pause.
Negative is the amount of compensation applied when you release the button, winding the motors back in the other direction
to resume tracking.
Normally both values should be the same. You will need to experiment with different values (from 0-99); a value between 20
and 50 is usually best for most visual observing, whereas a higher value may be necessary for photographic guiding.
To set the anti-backlash value, scroll down to the
anti-backlash option and press ENTER. While viewing an object in the
eyepiece, observe the responsiveness of each of the four arrow buttons. Note which directions you see a pause in the star
movement after the button has been pressed. Working one axis at a time, adjust the backlash settings high enough to cause
immediate movement without resulting in a pronounced jump when pressing or releasing the button. Now, enter the same
values for both positive and negative directions. If you notice a jump when releasing the button, but setting the values lower
results in a pause when pressing the button, go with the higher value for positive, but use a lower value for negative. The
telescope will remember these values and use them each time it is turned on until they are changed.
Filter Limits When an alignment is complete, the telescope automatically knows which celestial objects are above the
horizon. As a result, when scrolling through the database lists (or selecting the Tour function), the hand control will display
only those objects that are known to be above the horizon when you are observing. You can customize the object database by
selecting altitude limits that are appropriate for your location and situation. For example, if you are observing from a
mountainous location where the horizon is partially obscured, you can set your minimum altitude limit to read +20º. This will
make sure that the hand control only displays objects that are higher in altitude than 20º.
If you want to explore the entire object database, set the maximum altitude limit to 90º and the minimum limit to –90º.
This will display every object in the database lists regardless of whether it is visible in the sky from your location.
Direction Buttons The direction a star appears to move in the eyepiece changes depending on which side of the Meridian
the telescope tube is on. This can create confusion especially when guiding on a star when doing astrophotography. To
compensate for this, the direction of the drive control keys can be changed. To reverse the button logic of the hand control,
press the MENU button and select
Direction Buttons from the Utilities menu. Use the Up/Down arrow keys (10) to select
either the azimuth (right ascension) or altitude (declination) button direction and press ENTER. Select either positive or
negative for both axes and press ENTER to save. Setting the azimuth button direction to positive will move the telescope in
the same direction that the telescope tracks (i.e. towards the west). Setting the altitude buttons to positive will move the
telescope counterclockwise along the DEC axis.
Goto Approach - lets the user define the direction that the telescope will approach when slewing to an object. This allows
the user the ability to minimize the effects of backlash when slewing from object to object. Just like with
Direction Buttons,
setting
GoTo Approach to positive will make the telescope approach an object from the same direction as tracking (west) for
azimuth and counterclockwise in declination. Declination Goto approach will only apply while the telescope tube is on one
side of the Meridian. Once the tube passes over to the other side of the Meridian, the Goto approach will need to be reversed.
To change the Goto approach direction, simply choose
Goto Approach from the Scope Setup menu, select either Altitude or
Azimuth approach, choose positive or negative and press ENTER.
In order to minimize the affect of gear backlash on pointing accuracy, the settings for Button Direction should ideally
match the settings for GoTo Approach. By default, using the up and right direction buttons to center alignment stars
will automatically eliminate much of the backlash in the gears. If you change the Goto approach of your telescope it
is not necessary to change the Button Direction as well. Simply take notice of the direction the telescope moves when
completing its final goto approach. If the telescope approaches its alignment star from the west (negative azimuth)
and clockwise (negative altitude) then make sure that the buttons used to center the alignment stars also move the
telescope in the same directions.
Observing
Tip!
Helpful
Hint!
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Celestron CGE Pro 1400 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info