F 1 ~ F6 = RECOVERY HEART RATE LEVEL
u User press Test-key to start the H.R.C RECOVERY
u Get the result from F1 - F6.
Pulse Rate:
The whole set of heart rate detector include 2 sensors each side. Each
sensor has 2 pieces of metal parts. The correct way to detect is, to hold
gently both metal parts each hand. With the good signals picked up by the
computer, the heart symbol in the HEART RATE Display shall flash. Some-
times the heart rate value is not useable, based on wet hands or any other
contact problems during exercising. If you need high accuracy heart rate
value, you have to use an external heart rate measurement with a pulse
belt and pulse watch.
Exercising with App feature:
1. Download a desired APP depending on the operating system (APP
Store / Play Store) on your Smartphone/Tablet. (Note: The downloading of
apps maybe costs. Please observe the notes on any APP costs.)
2. Plug in the power for ergometer and place the smartphone/tablet di-
rectly to the tray of the computer to get a good connection continuously.
3. Activate the Bluetooth connection on your smartphone/tablet. (Should
this be already activated, deactivate the Bluetooth for short time and ac-
tivate new to terminate any remaining existing connections and thus to
obtain an interference-free Bluetooth connections. The smartphone/tablet
show you either immediately shortlist of available Bluetooth devices in your
environment or after open/launch the APP.
4. Select from the list the right devices and connect your smartphone/
tablet with the ergometer. On the backside of your ergometer computer is
a label with the Bluetooth device name, such as VISTA-BE - ??? ,
5. The ergometer computer beeps as soon as a Bluetooth connection is
done and displays the message „BT“. If the Bluetooth connection is ter-
minated the computer beep again and the display switch to start screen.
Cleaning, Checks and Storage of the Ergometer
bike:
1. Cleaning
Use only a less wet cloth for cleaning. Caution: Never use benzene,
thinner or other aggressive cleaning agents for surface cleaning as
this damage caused.
The device is only for private home use and for use suitable indoors.
Keep the unit clean and moisture from the device.
2. Storage
Plug out the power supply unit while intending the unit for more than
4 weeks not to use. Push the saddle slide toward the handlebar and
the seat support tube as deeply as possible into the frame. Choose
a dry storage in-house and put some spray oil to the pedal bearings
left and right, to the thread of the handlebar bolt, and on the thread
of the quick release for saddle support.
Cover the bike to protect it from being discolor by any sunlight and
dirty through dust.
3. Checks
We recommend every 50 hours to review the screw connections for
tightness, which were prepared in the assembly. Every 100 operating
hours, you should put some spray oil at the pedal bearings left and
right, to the thread of the handlebar bolt and to the thread of quick
release for saddle support.
Troubleshooting
If you cannot solve the problem with the following information,
please contact the authorized service center.
Problem Possible Cause Solution
Computer has
no value at Dis-
play if you press
any key.
No power
adapter is well
plugged or wall
power is without
power.
Check that the power adapter
is properly plugged in, possibly
with another electric device
check if the wall power is fine.
Computer is
not counting
data and do not
switch on after
start cycling.
Sensor impulse
missing base on
not well plugged
connection
Check the plug connections at
computer and inside of handle-
bar support.
Computer is
not counting
data and do not
switch on after
start cycling.
Sensor impulse
missing base on
not correct posi-
tion of sensor.
Take off the cover and check
the distance between magnet
and Sensor. The magnet at
turning belt wheel should have
only less than < 5mm distance
against the sensor position.
No pulse value Pulse cable is
not plugged in.
Check the separately pulse
cable is well connected with
computer.
No pulse value Pulse sensors
not well connec-
ted
Screw out the screw for pulse
measurement and check if
plugs are well connected and no
damage at pulse cable.
Training area in mm
(for home trainer and user)
Free area in mm
(Training area and security area
(rotating 60cm))
1.0 Outstanding
1.0 < F < 1.9 Excellent
2.0 < F < 2.9 Good
3.0 < F < 3.9 Fair
4.0 < F < 5.9 Below average
6.0 Poor
23

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Christopeit Blue-T1 - 1503 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info