7. Functions
In this chapter all possible indications are explained.
Whether these indications really appear, depends on whether or not they are switched on in the mo-
mentary current profile.
Some functions only appear in the altimeter mode , some only in the barometer mode .
This is indicated through an appropriate symbol in the single functions.
The functions in the upper display (chapter 5.1) can be called up with the
UR-button, the correspon-
ding sub-functions of the particular functions can be called up with the
UL-button.
The functions in the lower display (chapter 5.3) can be called up with the LR-button, the corresponding
sub-functions of the particular functions can be called up with the LL-button.
The functions in the medium display (chapter 5.2) can be called up by short pressing of the
MR-button.
There are no sub-functions of these functions.
Important: In order that the HAC5 calculates and displays all values (and saves them for the PC eva-
luation), a recording needs to be started (see also chapter 8.1). This happens by simultaneous pressing
of both left buttons for 3 seconds (the present profile is indicated in the display for 10 seconds and the
”-symbol flashes on top of the display as a sign for a running recording).
To stop the recording (at the end of the training) press both left buttons again simultaneously for
3 seconds (“
” stops flashing).
All minimum, maximum and average values (display indication: MIN/MA/AV) and also all daily values
(DAY) are only calculated when a recording was started.
This means: when the recording is not started during a training, the values of the last saved tour are
indicated in the above-mentioned displays, not of the present tour.
The sub-functions shift back automatically into the normal operational mode after 10 seconds.
7.1 Function indications of the upper display
Heartrate
Indicates the current heart rate.
Range: 20 – 250 bpm (beats per minute)
Note: The HAC5 can only indicate a heart rate when the appropriate transmitter belt is worn and this
function for the current program is switched on. The heart rate functions have a powerdown-mode:
when there is no impulse for approx. 10 minutes, the heart rate receiver (of the HAC5) switches off
automatically (instead of the HF indication in the text line the indication “HR: no TX” appears).
The heart rate receiver only restarts after a new transmitter search (e.g. by starting of a recording or by
a new selection of the function “current heart rate this function has to appear in the display for at
least 5 seconds).
Average heart rate
Sub-function of the current heart rate function.
IIndicates the calculated average heart rate in the upper display since the beginning of the present tour.
Range: 20 – 250 bpm
In the lower display the average heart rate of the personal maximum heart rate is indicated in per-
centage.
Range: 0 – 100%
Maximum heart rate
Sub-function of the current heart rate function.
Indicates the maximal reached heart rate during the recording in the upper display.
Range: 20 – 250 bpm
In the lower display the maximum heart rate of the personal maximum heart rate is indicated in per-
centage.
Range: 0 – 100%
Recovery heart rate
Sub-function of the current heart rate function.
Indicates the recovery heart rate (see also chapter 8.3).
The heart rate, which was measured at the beginning of this function, appears in the upper display. The
recovery heart rate, which was measured after 3 minutes, appears in the lower display.
Range: 20 – 250 bpm
Average heart rate
Maximum heart rate
Recovery heart rate
Function indications
of the upper display
Heartrate
Alti Mode Baro Mode
Value
139
Ø-Heartr.
71.6
%Pers.Max.
Value
192
Max-Heartr.
99.0
%Pers.Max.
High
174
Recovery HR
86
Low
B
B
A
A
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ciclo HAC 5 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Ciclo HAC 5

Ciclo HAC 5 Zusatzinformation - Deutsch - 4 seiten

Ciclo HAC 5 Kurzanleitung - Deutsch - 2 seiten

Ciclo HAC 5 Bedienungsanleitung - Deutsch - 38 seiten

Ciclo HAC 5 Zusatzinformation - Englisch - 4 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info