EnglishEnglish
Take the data of the number of resin liters from
the softener and set it using the “+” or “-” keys.
After having performed the water hardness tests
press the “+” or “-” keys to set the value on the
display (from 0 to 50 in steps of 5).
N.B. If a 0 value of water hardness is set, the
message “Regenerate Resin” will be deactivated.
Programming- Engineer Mode
Press “+” or “-” to change the key activation time
(from 0.0 to 120.0 in 5 second-steps).
If the key is set at “0.0”, once it has touched the
sensor it will remain activated. Touch the sensor
again to deactivate.
If another value is set, for example “10.0”, the
key will remain activated for 10 seconds after
the last operation.
Press one of the selection keys and with keys
“+” or “-” change the value meter increase “1” or
“2”.
Rest the “technician key” on the sensor.
Regeneration
Resin liters 1
Regeneration
Water hardness 1
Option
Key activation 20,0
Personalization
Press a key
Day Time
Technician