684051
37
Zoom out
Zoom in
Vorherige Seite
1/52
Nächste Seite
37
BAT
T1
M3 M4 M5
T3 T2
H1
4321
21
F1
100mA
Sensor Supply
Max. 60mA
Unit ONSteamServiceError
1 2 3 4 5 6 7 8 9 10
U1U2
Flap motor
0...10V / open...closed
Temperature out
0...10V / 0...100°C
FAN 1
(Exhaust)
FAN 2
(Supply)
FAN
Temperature or Humidity in
REMOTE
LINK UP
EXTERNAL CON.CPU BOARD
D+ D– GND 5V 24V
X15
J2
PEPESC2SC1NL1
X1
F1 6.3 AT
INLET DRAIN CONTA.
L'NL'N
X4
CONT. SIGN.
GNDINV+
X10
JP3
L'N
X3
24V 5V
5V
24V
SAFETY CHAIN
CONTACTORDRAININLETSC SYSTEM
LEVEL SENSOR
GND
SWITCH
L1FUNL1SWNSW
X2
SC
L'N
X16
S1S2
LEVEL SENS.
CURRENT SENSOR
X5
MAIN SUPPLYMODULE B
PEP1NP
X6
LIM. SIGN.
GNDIN
EXT. SUP.
5V GND 24V
X11
X14
F4 315mAT
F3 315mAT
J1
J4
+
A6
L1 L2 L3
Q8
K1
XE1
F8
L1 L2 L3
L1 L2 L3
400 V/3~/50..60 Hz
230 V/3~/50..60 Hz
Q8
F8
L1 N PE
PE
PE
230 V/1~/50..60 Hz
Q8
F8
L1 L2
400 V/2~/50..60 Hz
PE
Premium Pro
ext.
N
N
PE
L1
L1
Q9
230 V/1~/50..60 Hz
L N PE
F9
XE3
2-Fan
Mode
Supply FAN
(Light 24 V)
Supply Light
24V
230V
12V
12V 12V
230V 230V
Internal
Mode
External
Mode
230V
24V
12V
max. 2m
24V
24V / 12V
Supply on site
24V
18V
230V
L N L N LL N N
230V 12V
L N
230V 24V
15V
0V
1-Fan
Mode
1-Fan
Mode
X25
NO NOAUX1 AUX2COM COM
FAN 1
2-Fan Mode
FAN 2
X23
COM NO COM NO
REL8 REL9
X26
FAN 0VAC
1-Fan Mode
X6
1234
PE
P1
N
P
MODULE B
X24
SC2
SC1
21
SAFETY CHAIN
8 A 250 VAC
8 A 250 VAC
8 A 250 VAC
8 A 250 VAC
8 A 250 VAC
8 A 250 VAC
8 A 250 VAC
8 A 250 VAC
8 A 250 VAC
X27
FAN 0V
LIGHT SUPPLY OUT
J2
EXT. TRAFO IN
24V 0V18V15V
X21
L NN LL N
LIGHT 1 LIGHT 2LIGHT IN
X22
L' L'N NPE PE
PUMP 1 PUMP 2
X14
EXT. SUPPLY IN
5VGND24V
X31
J3J4
TEMP S
24V
GND
TEMP IN
24V
LIGHT 2
LIGHT 1
BATH I/O
DOOR
1234 5678 9
INPUTS
F6
315mAT
F5
230V: 1AT
24V: 4AT
12V: 6.3AT
F7
4AT
CPU BOARD
J3
T4
T4
H3
H2
M2
M1
M2
M1
H3
H2
SW4
SW3
SW2
SW1
A5
Unit 2Unit 3Last Unit
D+ D– GND 5V 24V
X15
D+ D– GND 5V 24V
X15
D+ D– GND 5V 24V
X15
JP1
JP4
JP5
JP1
JP4
JP5
JP1
JP4
JP5
Remote Terminal
D+ D– GND 5V 24V
X15
JP1
JP4
JP5
from contactor to cylinder
JP1
JP4
JP5
J9
J1
J4
J1
X1
X4X5
J2
J3
Excess temperature
switch
Temperature sensor
5.6 Electric installation 5.6.1
Wiring diagram Cleo Premium Pro
A5 Temperature sensor with excess temperature switch (e.g. KTY)
A6 Temperature sensor 0...10 V
BAT Backup battery (CR2032, Lithium 3V)
F1 Internal fuse “Power board” (6.3 A, slow acting)
F3 Internal fuse “Power board” 24 VDC supply (315 mA, slow acting)
F4 Internal fuse “Power board” 5 VDC supply (315 mA, slow acting)
F6 Internal fuse “steam bath board”
24 V supply (315 mA, slow acting)
F5 Internal fuse “steam bath board”
Light (230 V: 1 A, slow acting,
24 V: 4 A, slow acting, 12 V: 6.3 A, slow acting)
Control board
Power board
F7 Internal fuse “steam bath board” Fan
(4 A, slow acting)
F8 External fuse heating voltage supply
F9 External fuse control voltage supply
H1 Remote operating and fault indication
H2 Light 1
H3 Light 2
J3 Short circuited, if no excess temperature
switch is connected
J4 Short circuited, if no door switch is connected
JP1 End resistor Remote Terminal
JP3 Jumper control signal
JP4 Pull up resistor Remote Terminal
JP5 Pull down resistor Remote Terminal
K1 Main contactor
M1 Fragrance pump 1
M2 Fragrance pump 2
Steam bath
board
M3 Exhaust air fan 1 (2 fan mode)
M4 Supply air fan 2 (2 fan mode)
M5 Fan (1 fan mode)
Q8 External service switch heating voltage supply
Q9 External service switch control voltage supply
SW1 Door switch steam bath cabin
SW2 On/Off push-button steam bath cabin
SW3 On/Off push-button light 1
SW4 On/Off push-button light 2
T1 Transformer voltage supply fan
T2 Transformer voltage supply light (230V/12V)
T3 External transformer voltage supply light (230V/12V)
XE1 Connection terminal heating voltage
XE3 Connection terminal control voltage
X15 Connection terminal remote panel
U1 External temperature indication (0...10 V / 0...100 °C)
U2 Flap actuator (0...10 V / open...closed)
37

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cleopatra Cleo Premium Pro wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.