Installation tool/ Installation sequence
Dimensions
The panel is movable 00 mm downward.
The stated dimensions refer to the highest position of the panel.
Technical Data
Note
Points out information to the aected personnel, whose content
is important and must be taken into consideration.
Water connection
Warm water
Water connection
Cold water
Installation sequence
Silicone (free from acetic acid!)
Observe all current and water lines when
drilling!
Technical Data
Operating pressure: max. 1,0 MPa
Recommended operating pressure: 0, - 0,5 MPa
Test pressure: 1,6 MPa
Hot water temperature: max. 80° C
Recommended hot water temp.: 65° C
Connections G 1/
Rate of ow by 0, MPa:
hand shower 15,4 l/min
body showers, _1a pieces 14,5 l/min
overhead shower 1,7 l/min
overhead shower + body showers 0,5 l/min
hand shower + body showers 1 l/min
Flow heater
Applicable for ow heaters at min. 4 kW and 0,15 MPaow pressure before the
Shower panel and a minimum through ow of 7 l/minute. Only one consumer possible,
not two simultaneously.
Pressure dierences
The pressures of the cold and hot water connections must be balanced.
non return valve
The non return valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
Wall mount (see page 64)
Corner installation (see page 68)
Special accessories
corner tting set (61X000 ) order as an extra
Installation Instructions
Check for required minimum height of 00 mm from shower tray oor
before starting installation
The indicated installation dimensions apply to a person that is about
1,8000 mm tall. If the dimensions have to be adapted to shorter or
taller persons, you must make sure that the minimum tub standing height
of ,00 mm will also change. This will also alter the connection and
boring hole dimensions.
Gloves should be worn during installation to prevent crushing and
cutting injuries.
Where the contractor mounts the product, he should ensure that the
entire area of the wall to which the mounting plate is to be tted, is at
(no projecting joints or tiles sticking out), that the structure of the wall is
suitable for the installation of the product and has no weak points. The
enclosed screws and dowels are only suitable for concrete. For another
wall constructions the manufacturer’s indications of the dowel manufac-
turer have to be taken into account.
The mesh washers must be installed to protect against incoming dirt by
pipework. Incoming dirt can impair the function and/or lead to dama-
ges on functional parts of the xture; HansGrohe will not be held liable
for resulting damages.
The arm of the shower head is intended only to hold the shower head.
Do not load it down with other objects!
Important! The tting must be installed, ushed and tested after the valid
norms.
Operation (see page 74)
The shower system may only be used for bathing, hygienic and body
cleansing purposes.
Children as well as adults with physical, mental and/or sensoric
impairments must not use this shower system without proper supervision.
Persons under the inuence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch sensitive body parts (such
as your eyes). An adequate distance must be kept between the shower
and you.
The product may not be used as a holding handle. A separate handle
must be installed.
English
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

cleopatra-pharo-lift-2

Suche zurücksetzen

  • Sehr geehrte Damen und Herren,
    Wir haben seit 30.12.2008 eine Pharo Lift 2 und sind bisher sehr zufrieden damit.
    Nun ist es aber so, dass aus der Kopfbrause (Wasserdruck Leitung ca. 2,5 bar) und aus
    den Seitenbrausen (beide Einrichtungen selten gebraucht) kein Wasser (4 Seitenbrausen) oder nur noch wenig (2 Seitenbrausen) Wasser kommt. Handbrause arbeitet einwandfrei.
    Was kann die Ursache sein? Verstopfungen durch Kalkablagerungen?
    Was kann ich tun?
    Wie löst man die Seitenbrausen aus dem Panel um sie ggf. zu reinigen?
    Gibt es einen Fachbetrieb in unserer Nähe? PLZ 55413
    Vielen Dank im Voraus
    Mit freundlichen Grüßen
    Günter Grimm
    Tel.: 06743 6023 Eingereicht am 4-6-2021 17:32

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cleopatra Pharo Lift 2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info