5
• The device should be kept in an environment clean of dust or any kind of dirt. This will
avoid spots or stains from appearing on the walls behind the unit. Our units do not have
any combustible element inside and the appearance of spots is consequence of
environmental reasons.
• Might there be any failure or damage on the connection wire, a qualified electrician, the
technical service or the manufacturer should be the ones to replace it (3x1,5 mm2).
• The plug should only be connected in the proper same technical conditions socket.
2.3.- MANUFACTURER’S WARNINGS
Any manipulation on the device for reparation or maintenance must be done by the
corresponding Technical Assistance Service or by a qualified electrician always keeping the
device properly unplugged and using original spare parts (the manufacturer will not be
responsible for the deterioration of the radiator when the damage is produced by the use of
non- original spare parts).
The following data must be supplied to refer any communication related to the acquired heating
device:
• Invoice number
• Dealer
• Serial Number (the heating system’s characteristics plate is located on the side of the
device. The plate holds the serial number and the technical characteristics of the system).
• Purchasing date.
• Detailed information of the malfunctioning.
Before contacting the technical service or your distributor, please take a look at section “10-
FAQs”.
3.-BEFORE CONNECTING THE DEVICE
• Make sure the supply voltage corresponds to the one indicated on the rating plate (located
on the left side of the device). The electrical power is supplied through the plug with the
power cord.
• Check that the device’s or other connection wires are not in contact with the device’s surface.
• The devices in all their configurations are fitted with a expelling valve installed on the heat
exchanger
• Once the device is installed the circuit should be purged using the mentioned valve.
• Treat the water in order to maintain a PH between 5 and 8.
• All the devices have been tested for leaks with a pressure of 20 bar. The maximum working
pressure should not exceed 10bar.
• The device features female ½” fittings.