Before installation
Connecting to Ø150 mm exhaustair duct
Attach the enlarging adapter (enclosed or
available from specialist dealer) to the air
outlet. Attach the exhaust-air duct to the
adapter.
If a backflow flap has been installed, check
that it functions properly.
Circulating-air mode
With activated carbon filter if exhaust-air
mode is not possible.
The air purified by an additional activat-
ed carbon filter is returned to the room.
After installing the extractor hood, insert
the activated carbon filter.
For installing see Filters and maintenance.
If the extractor hood is installed beneath a
cabinet, ensure that there is an adequate air
outlet (min. 177 cm
2
).
The extractor comes as standard equip-
ped with a protective grid in the air connec-
tor. If this is has been removed (in the case
of exhaust air operation), the air connector
must be supplemented by a reducer piece
with protective grid (see section on special
accessories).
WARNING:
THIS APPLIANCE MUST BE EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the power cord are colourcod-
ed as follows:
Green and Yellow – Earth
Blue Neutral
Brown – Live
If you fit your own plug, the colours of these
wires may not correspond with the identify-
ing marks on the plug terminals.
Proceed as follows:
1. Connect the green and yellow (Earth)
wire to the terminal in the plug marked
‘E’ or with the symbol ( ), or coloured
green or green and yellow.
2. Connect the blue (Neutral) wire to the ter-
minal in the plug marked ‘N’ or coloured
black.
3. Connect the brown (Live) wire to the ter-
minal marked ‘L’, or coloured red.
The extractor hood may be connected
to a correctly installed earthed socket only.
Attach the earthed socket near the extrac-
tor hood in an accessible position.
q The earthed socket should be connec-
ted via its own power circuit.
If appliances do not feature the OFF
delay function, the indicator may start flas-
hing when the extractor hood has been
switched off for several hours via a separate
switch, even though the grease filters are
not yet saturated.
(See Filters and maintenance).
Electrical specifications:
These can be found on the rating plate
inside the appliance following removal of
the filter frames.
Before carrying out repairs, always
isolate the appliance.
Length of the connection cable: 1.30 m.
If permanent connection is required:
The extractor hood may only be con nected
by an electrician registered with the local
electricity board.
A disconnecting device must be provided
on the installation side. Switches with a
contact opening of more than 3 mm and
all-pole disconnection are regarded as dis-
connecting devices. These include LS
switches and contactors.
If the connecting cable for this applian-
ce is damaged, the cable must be replaced
by the manufacturer or his customer service
or a similarly qualified person in order to
prevent serious injury to the user.
This extractor hood complies with EU regu-
lations on interference suppression.
Electrical connection Installation
Please note: A wall hanging set can be
obtained from your dealer (see section on
special accessories) for fastening the hood
(e.g. at the end of the row of kitchen units).
The extractor hood is designed for
installation between two wall cabinets.
1. Remove grease filter
(see Filters and maintenance)
2. Using the enclosed template mark the
positions of the screws on the side pan-
els of the neighbouring cabinets.
The extractor hood can also be installed
slightly lower, depending on the height of
the wall cupboards. Position the template
correspondingly lower.
Observe the minimum distance from hob to
extractor hood of
650 mm (the fixing
screws
must be fitted at least 1040 mm
above the hob
).
3. Predrill (with bradawl or 2 mm bit) and
screw in the screws to 5 mm.
4. Suspend the extractor hood on the two
screws between the wall cabinets.
5. The two door carriers of the extractor
flap must be pushed into the appliance
to he stops.
6. Align the extractor
hood with the lea-
ding edge of the
side cabinets.
34
34
20
20
5 mm
37

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Constructa CD22130 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info