.2Caution
Caution
Caution
Caution
1.Thefingershouldbeplacedproperly(seetheattachedillustrationofthismanual,Figure5),or
else
it
maycauseinaccuratemeasurement.
2.TheSpO
2
sensorandphotoelectricreceivingtubeshouldbearranged
in
awaywiththe
subject
sarteriole
in
apositiontherebetween
3.TheSpO
2
sensorshouldnotbeusedatalocationorlimbtiedwitharterialcanalorblood
pressurecufforreceivingintravenousinjection.
4.Makesuretheopticalpathisfreefromanyopticalobstacleslikerubberizedfabric.
5.Excessiveambientlightmayaffectthemeasuringresult.Itincludesfluorescentlamp,dualruby
light,infraredheater,directsunlightandetc.
6.Strenuousactionofthesubjectorextremeelectrosurgicalinterferencemayalsoaffectthe
accuracy.
7.Testeecannotuseenamelorothermakeup.
3
3
3
3.3
.3
.3
.3Clinical
Clinical
Clinical
Clinical
r
r
r
r
estrictions
estrictions
estrictions
estrictions
1.Asthemeasureistakenonthebasisofarteriolepulse,substantialpulsatingbloodflowof
subjectisrequired.Forasubjectwithweakpulseduetoshock,lowambient/bodytemperature,
majorbleeding,oruseofvascularcontractingdrug,theSpO
2
waveform(PLETH)willdecrease.
Inthiscase,themeasurementwillbemoresensitivetointerference.
2.Forthosewithasubstantialamountofstainingdilutiondrug(suchasmethyleneblue,indigo
greenandacidindigoblue),orcarbonmonoxidehemoglobin(COHb),ormethionine(Me+Hb)
orthiosalicylichemoglobin,andsomewithicterusproblem,theSpO
2
determinationbythis
monitormaybeinaccurate.
3.Thedrugslikedopamine,procaine,prilocaine,lidocaineandbutacainemayalsobeamajor
factorblamedforseriouserrorofSpO
2
measure.
4.AstheSpO
2
valueservesasareferencevalueforjudgementofanemicanoxiaandtoxicanoxia,
somepatientswithseriousanemiamayalsoreportgoodSpO
2
measurement.
4
4
4
4Technical
Technical
Technical
Technicalspecifications
specifications
specifications
specifications
4
4
4
4.
.
.
.1
1
1
1Display
Display
Display
DisplayFormat:
Format:
Format:
Format:DigitaltubeDisplay;
SpO
SpO
SpO
SpO
2
2
2
2
M
M
M
Measur
easur
easur
easuring
ing
ing
ingRange
Range
Range
Range:
:
:
:0%-100%;
Pulse
Pulse
Pulse
PulseRat
Rat
Rat
Rate
e
e
eM
M
M
Measur
easur
easur
easuring
ing
ing
ingRange
Range
Range
Range:
:
:
:30bpm-250bpm;
Pulse
Pulse
Pulse
PulseIntensity
Intensity
Intensity
IntensityDisplay:
Display:
Display:
Display:columniationdisplay
4
4
4
4.2
.2
.2
.2Power
Power
Power
PowerRequirements:
Requirements:
Requirements:
Requirements:2×1.5VAAAalkalinebatteryorusingtherechargeablebattery
instead,adaptablerange:2.6V~3.
6V.
4
4
4
4.
.
.
.3
3
3
3Power
Power
Power
PowerConsumption:
Consumption:
Consumption:
Consumption:Smallerthan25mA.
4
4
4
4.4
.4
.4
.4Resolution:
Resolution:
Resolution:
Resolution:1%forSpO
2
and1bpmforPulseRate.
4
4
4
4.
.
.
.5
5
5
5Measurement
Measurement
Measurement
MeasurementAccuracy:
Accuracy:
Accuracy:
Accuracy:±2%
in
stageof70%-100%SpO
2
,andmeaninglesswhenstage
beingsmallerthan70%.±2bpmor±2%(selectlarger)forPulseRate.
4
4
4
4.
.
.
.6
6
6
6Measurement
Measurement
Measurement
MeasurementPerformance
Performance
Performance
Performancein
in
in
inWeak
Weak
Weak
WeakFilling
Filling
Filling
FillingCondition:
Condition:
Condition:
Condition:SpO
2
andpulseratecanbeshown
correctlywhenpulse-fillingratiois0.4%.SpO
2
erroris±4%,pulserateerroris±2bpmor±
2%(selectlarger).
4
4
4
4.
.
.
.7
7
7
7Resistance
Resistance
Resistance
Resistanceto
to
to
tosurrounding
surrounding
surrounding
surroundinglight:
light:
light:
light:Thedeviationbetweenthevaluemeasured
in
thecondition
ofman-madelightorindoornaturallightandthatofdarkroomislessthan±1%.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Contec CMS50DL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info