DIVE-SET MODE: Diving parameters setting.
Once the MODE SET (MODE-S) menu is set in AIR or NITROX mode you can modify the parameters by
accessing the next menu DIVE SET (DIVE-S).
IMPORTANT: If the screen displays the battery icon with a single segment on, the computer MUST NOT
be used. The battery can be replaced by the user, as we shall see in the corresponding chapter
IMPORTANT: Once changing from NITROX SET MODE to AIR SET MODE, the parameters of both Mix1
and Mix2 return to the values 21% (FO2) and 1.4 bar (PO2).
PARTIAL OXYGEN PRESSURE (PO2)
Newton is factory set with a Partial Oxygen Pressure (PO2) value of 1.4 bar both for the air dives and Nitrox
dives with one or two mixtures (Mix1 and Mix2) in order to ensure the maximum safety during any type of dive.
However, the PO2 can only be modified if the computer is set in NITROX SET MODE in values between 1.2 bar
(included) and 1.6 bar (included) with variations of 0.1 bar. In case you need to increase the safety margin of
the dive, it will be possible to set PO2 to lower values, up to a minimum of 1.2 bar.
Mix1 Partial Oxygen Pressure (PO2) setting.
Press the UP button to move up to dive set mode (DIVE-S). Enter in this mode by pressing the Mode button and
the partial oxygen pressure (PO2) indication and the Mix1 indicator will flash. Now press the Mode button
again. The display will show just the highlighted item, flashing together with the corresponding maximum
operating depth. Set the desired values (between 1.2 and 1.6 bar, with variations of 0.1 bar) by pressing the UP
or DOWN button. Confirm the value set by keeping the Mode button pressed for a few seconds until hearing an
acoustic signal to confirm exit from the menu. Keep pressing and holding the Mode button to return to the main
menu (after another acoustic signal). Alternatively, the computer will modify the automatic setting by issuing an
acoustic signal to return then to the main screen.
Mix2 Partial Oxygen Pressure (PO2) setting.
Press the UP button to move up to dive set mode (DIVE-S), enter in this mode by pressing the Mode button.
The indication of the partial oxygen pressure (PO2) and the Mix1 indication will flash. Press the UP button
twice. The word Mix2 will appear together with the PO2 value. Now press the Mode button again. The display
will show just the highlighted item, flashing together with the corresponding maximum operating depth. Set the
desired values (between 1.2 and 1.6 bar, with variations of 0.1 bar) by pressing the UP or DOWN button.
Confirm the value set by keeping the Mode button pressed for a few seconds until hearing an acoustic signal to
confirm exit from the menu. Keep pressing and holding the Mode button to return to the main menu (after
another acoustic signal). Alternatively, the computer will modify the automatic setting by issuing an acoustic
signal to return then to the main screen.
IMPORTANT: the computer maintains the PO2 setting until it is manually reset by the diver on different values
or until the MODE-S menu is set in AIR.
REMARK: By varying the maximum PO2 set and the percentage of oxygen in the FO2 mixture, the computer
indicates the maximum depth which may be reached.
IMPORTANT: The PO2 is set by the manufacturer on the default value of 1.4 bar, for both air dives and Nitrox
dives. This way, the safety of the diver is ensured by following the most conservative values recommended for
sport dives. However, you can select another PO2 value, as indicated in the chapter on Nitrox dives. The value
set will be saved in the computer until the diver resets it or until the MODE-S menu is set in AIR.
NITROX PERCENTAGE OF OXYGEN (FO2)
The percentage of oxygen FO2 can be changed only when the computer is set in SET NITROX MODE. With
this setting you can decide the type of dive: with air (Dive Air Program), with fraction of oxygen at 21%, or using
one or two Nitrox hyper-oxygenated mixtures (Dive Nitrox Program).
Mix1 percentage of oxygen (FO2) setting
To set the correct percentage of Oxygen contained in the Nitrox mixture, press the UP button to move up to the
DIVE-S mode. Enter in this mode by pressing the Mode button. The indication of the partial oxygen pressure
(PO2) and the Mix1 indicator will flash. Press the UP button. The indicator of the percentage/fraction of oxygen
(FO2) will flash. Press the Mode button. The display will show just the highlighted item (FO2), flashing together
with the corresponding maximum operating depth that can vary by pressing the UP or DOWN button of the
device. Once the desired setting is reached (values between 21% and 50% with variations of 1% of O2),
confirm the value set by keeping the Mode button pressed for a few seconds until hearing an acoustic signal to
confirm exit from the menu. Keep pressing and holding the Mode button to return to the main menu (after
another acoustic signal). Alternatively, the computer will modify the automatic setting by issuing an acoustic
Po2 MIX1 - PARTIAL OXYGEN PRESSURE SETTING MIXTURE 1
PO2 MIX2 - PARTIAL OXYGEN PRESSURE SETTING MIXTURE 2
INDEX
9
LONG
BEEP
LONG LONG LONG
BEEP BEEP BEEP
LONG
BEEP
LONG
BEEP
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cressi NEWTON wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info