ON SURFACE AFTER DIVING
DATA DISPLAY AND MANAGEMENT.
This chapter deals with all the "on surface" functions, including data processing after a dive. By using the UP or
DOWN button, it will be possible to activate in sequence the Following functions: LOG BOOK (dive log),
HISTORY (dive history) and PC LINK (Data transfer to PC by means of interface).
SURFACE INTERVAL.
After a dive with AIR DIVE MODE or NITROX DIVE MODE function, when you reach depths below 0.8 m, the
display provides the following information:
1) Surface interval given in hours and minutes (SURF.T)
2) Desaturation time (DESAT) to be respected before embarking on a flight (in hours and minutes).
2) NO FLY icon. It means that flights or travel to higher altitudes than the current altitude must be avoided.
3) Max depth reached in the latest dive.
4) Duration of the latest dive.
5) Eventual alarms issued during dive (ascent rate, partial pressure of oxygen)
6) Indication of the altitude (if applicable).
7) DECO icon if decompression has been performed.
8) NX indication and O2 toxicity bar if the latest dive has used Nitrox
IMPORTANT: Following the indications of the major organisation which study diving and hyperbaric medicine,
Newton applies the no flight times as follows:
12 hours after a single dive with no decompression limits.
24 hours after a dive with decompression or after repetitive or multiday, of correctly performed.
48 hours after the use of the gage function or if severe mistakes in dive management occurred.
REMARK: Should a dive begin with less than 2 minutes of surface interval time, Newton will consider it a
continuation of the previous dive: the number of dives remain the same and the calculation of the duration
restarts from where they had stopped. Dives carried out after at least 2 minutes of surface are considered as a
new dive.
In the case the dive is performed with the GAGE function the device will not perform any saturation or
desaturation calculation during the 48 hours elapsing from the end of the dive performed, represented by the
surface interval SURF.T.
PLAN FUNCTION DIVE PLAN.
The PLAN function takes into account the residual nitrogen in the tissues after the dive/s performed, changing
the decompression times and making them shorter than those indicated for a first dive.
REMARK: The PLAN function is disabled in the GAGE function (depth gauge/timer) and if the computer shows
"error".
LOG BOOK FUNCTION DIVE LOG.
Newton by Cressi stores data about the last 60 dives. Data is recorded every 20 seconds in the LOG BOOK. To
display the previous dives, press and hold the UP button until the word LOG appears. The latest dive will be
displayed in chronological order. To display the data related to the previous dives, press the Mode button so
that the dive number flashes. Then, press the UP or DOWN button to move forward or backward to the desired
one. The LOG BOOK presents two screens for each dive with single mixtures and three screens for the dives
performed with two mixtures. To display the second screen of dive, once reached the dive number desired,
press the Mode button. In case the dive is performed with two mixtures GAS SWITCHING, once the second
screen is displayer, to see the third one, you will need to press the UP button. In both cases the data remains
displayed for 20 seconds after that, the computer will automatically return to the main menu. Keep pressing the
UP or DOWN button and you will see in the three screens with the dive data.
The LOG BOOK function, therefore, enables to display, by means of two or three screens, of a complete series
of data related to the dives performed, starting from the most recent dive in chronological order.
The main screen displays the following information:
· Dive's year, month, and day.
· Dive number: the most recent dive's information is given first. When more than 60 dives are carried
out, the oldest dives are deleted.
AIR SURFACE INTERVAL
NITROX SURFACE INTERVAL
PLAN FUNCTION
AIR LOG BOOK
19
GAGE
TIME DISPLAY
LOCKED DIVE COMPUTER
TIME DISPLAY
INDEX
AUTOMATIC
RETURN OR
WITH LONG
MODE BUTTON
BEEP
AUTOMATIC
RETURN OR
WITH LONG
MODE BUTTON
BEEP
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cressi NEWTON wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info