736615
20
Zoom out
Zoom in
Vorherige Seite
1/25
Nächste Seite
- 75 -
Other
Back light
Important safety information
ATTENTION:
Consult your doctor before you begin any
training program. Your doctor can help you choose the
proper training intensity and heart rate guidelines for your
exercises.
This heart rate wrist watch is not a medical device and should
only be used as a guide for your training.
- Batteries
Insert the batteries/ rechargeable batteries in the correct polarity. Don’t try to
recharge non-rechargeable batteries and under no circumstances throw them into
fire. Danger of explosion.
Do not use unequal batteries (old and new, Alkaline and carbon, etc.)
simultaneously. If you will not use the device for a long time, remove the batteries
and store the device in a dry and dust-free place. Improper use of batteries may
cause an explosion or leakage. If the batteries have leaked, use gloves and clean
the appliance thoroughly with a dry cloth.
- Electrical devices should not be in the hands of children
Never let children use electrical devices unsupervised. Children can’t always
recognize the possible dangers properly. Batteries/ rechargeable batteries can
be life threatening when swallowed. Store the batteries where they cannot be
reached by small children. If a battery is swallowed, medical aid must be sought
immediately.
Also keep the packaging foils away from children. Danger of suffocation.
- 76 -
Setup of the heart rate monitor
Use a coin to unscrew the battery cover on the back side of the chest belt and
insert the 3V battery with the (+) sign facing up. Screw the battery compartment
cover back into the case.
Remove the protective film from the display and press MODE, SEL or SET.
Now select English, German, French or Spanish language by pressing SEL and
confirm your setting by pressing SET.
Select the unit KM-KG
METRIC KM - KG KM - KG KM - KG
or Miles/pounds
IMPERIAL M - LB M - LB M - LB
in the same way. Complete the setting procedure by pressing MODE.
battery CR2032
- 77 -
Reset
The watch can be reset by pressing and holding SET and SEL together. Only after
reseting the watch the other language can be selected.
Replacing the watch battery
The battery replacement can be performed by a watch maker in addition to a
water resistance test.
To replace the battery yourself, please read the following instructions first:
Remove the screws (1, 2, 3 and 4) from the back side of the watch with a small
Phillips screwdriver. Remove the caseback and the battery sticker.
Use a small, flat tool to open the latch (5) of the battery holder. Remove the
battery and insert a fresh 3V CR2032 battery with the (+) terminal facing upwards.
Ensure that the gasket (6) is seated correctly. Close the latch of the battery holder.
Replace the battery sticker and the caseback and replace the screws.
Battery low indicator
If the battery voltage on the chest belt battery drops below the voltage required for
normal operation,
TXBELT
LO BAT
TXGURT
BATT
SNGLTX
PILE
TXBCIN
BAT BA
will appear on the display. Replace the battery of the chest belt as described in the
chapter "Chest belt".
- 78 -
Wearing the chest belt
Adjust the chest belt so that it fits
snugly directly below the chest
muscles. Moisten the contact
areas with water or ECG gel
(ECG gel can be purchased at a
pharmacy). Ensure that the contact
areas constantly remain in skin
contact.
Position the chest belt as per the
following illustration.
Please ensure that the chest belt is
seated properly. When you have
exhaled completely the chest belt
should still have very slight tension
pressing it to your chest.
High voltage power lines, Trains
or moving vehicular traffic may
interfere with the heart rate
measurement. Please consider this
when planning your exercise
route.
Coded transmission
The chest belt's transmissions are digitally coded to prevent interference if you are
training with a training partner who is using an identical watch and chest belt.
When using the chest belt for the first time, a random channel is selected
automatically. The channel is briefly displayed at the top of the display upon
entering the heart rate display mode. The available channels are CH10, CH11,
CH12, CH13 and CH14.
The channel can be changed by briefly removing the battery from the chest best
and reinserting it. The chest belt will randomly select a channel and after approx. 1
minute the heart rate and the new channel will appear on the display of the watch.
contact area
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Crivit 1-LD3814 IAN 47584 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info