648531
3
Zoom out
Zoom in
Vorherige Seite
1/8
Nächste Seite
EN  •  3
3. Normal charging will be indicated by the following lights: start (1), bulk charging (2), absorption charging (3) or mainte-
nance charging (4). When the maintenance charging lamp illuminates the battery is fully charged. Charging will start 
if the voltage drops. The charger can normally be connected for months. Reconditioning is indicated by the lamp (5) 
illuminating. 
4. If the battery leads have been connected incorrectly, the reverse polarity protection system will ensure that neither the 
charger nor the battery is damaged and is indicated by lamp (0).
5. If nothing happens. If the lamp indicating the setting and the power lamp remain lit but no other lamp illuminates, the 
connection to the battery or chassis may be poor or the battery may be faulty. Another cause may be a lack of voltage in 
the AC Power Supply. Begin by improving the connection between the battery and charger.
6. Charging can be stopped at any time by disconnecting the charger’s AC cord. Always disconnect the AC cord before 
disconnecting the battery leads. When you stop charging a battery installed in a vehicle you should always disconnect 
the battery lead from the chassis before disconnecting the other battery lead.
IMPORTANT INFORMATION
Please note that the battery pack in the 24V system in most cases consists of more than one battery. They are linked up to 
the 24V system, but the individual batteries generally have a lower voltage. Therefore it is important for the charger to be 
connected correctly. 
BATTERY TYPES AND SETTINGS
The charger is programmed according to “PROGRAM DESCRIPTION” with xed settings and can easily be set for 
different types of batteries or conditions. The following recommendations should, however, only be seen as guidelines. 
Please consult the battery manufacturer for further instructions. 
Settings are made by pressing the “MODE-button “ and stepping forward one press at a time until the required mode is 
reached, the button is then released. After about 2 seconds the charger activates the selected mode. The selected mode 
is saved in a memory in the charger and remains there even if the charger is disconnected from battery and mains.
NORMAL
NORMAL - Normal setting for wet batteries, maintenance free and for most Gel batteries. Some Gel 
batteries prefer a slightly lower charging voltage. Please consult the battery manufacturer when in 
doubt.
SUPPLY
SUPPLY - The charger operates at a constant voltage. This is the maintenance mode for applications 
where maximum capacity from the battery is important, like oor sweepers and golf carts. Note that 
the Spark protection function is suppressed in this mode.
RECOND
RECOND - This mode is used to recover deep discharged ooded batteries where you could expect 
a stratied acid (high acid weight in the bottom, low on top). Check with battery manufacturer when 
in doubt. 
Use this mode with care, because the high voltage will cause some water loss. 32V is normally no 
problem for electronics in 24V system. Consult your supplier when in doubt. Life of light bulbs will be 
reduced at higher voltage. Try to disconnect light from the battery during this phase. Maximum effect 
and minimum risk for electronics is achieved by charging a disconnected battery.
CHARGING PHASES
MXT 14000 AE charges and analyses in eight fully automatic steps.
The battery charger has an 8-step fully automatic charging cycle:
Desulphation
Desulphation with pulses recovers sulphated batteries. Indicates with lamp 1.
Start (Lamp 1)
Start mode for the charging cycle. The start phase continues until the battery’s terminal voltage has risen above the set 
limit, at which point the charger switches to bulk charging. If the terminal voltage has not passed the voltage limit within 
the time limit, the charger switches to fault mode (lamp 0) and discontinues the charging. If so, the battery is faulty or its 
capacity is too large. 
Bulk (Lamp 2)
Main charge when 80% of charging takes place. The charger delivers maximum current until the terminal voltage has risen 
to the set level. Bulk has a maximum time, at which point the charger automatically switches to Absorption.
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ctek MXT 14000 AE wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Ctek MXT 14000 AE

Ctek MXT 14000 AE Bedienungsanleitung - Deutsch - 10 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info