29
SPECIFICATIONS
MODEL DSB-181LH
Function Cooling / Heating (Heat pump)
Power Supply AC 220
-
240V, 50Hz
Cooling Capacity (Heating) 4,400 Kcal/h (4,600 Kcal/h)
Operating Current (Heating Mode) 9.65 A (10.0 A)
Power Consumption (Heating Mode) 2,150 W (2,235 W)
Indoor Unit Dimensions W 1035 x H 322 x D 205 mm
Outdoor Unit Dimensions W 800 x H 615 x D 277 mm
Net Weight
Indoor 12.1 kg
Outdoor 51.9 kg
Connection
Type Flare
the piping
Gas 1/2" (12.7 mm)
Liquid 1/4" (6.35 mm)
Air Cleaning Anti-bacteria Filter, Electrostatic Filter, Deodorizing Filter
Operating Indoor side (Heating Mode) min 21˚C ~ max 32˚C (min 15˚C ~ max 27˚C)
Condition Outdoor side (Heating Mode) min 21˚C ~ max 43˚C (min -5˚C ~ max 24˚C)
Design and specification are subject to change without notice for product improvemont.