554160
12
Zoom out
Zoom in
Vorherige Seite
1/24
Nächste Seite
4 Operation
User reference guide
12
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
To read out and adjust the desired reheat
temperature (in reheat mode)
1 Go to the DHW tank temperature home page (Tank).
Result: You can read out the desired reheat temperature.
2 Press or to adjust.
Note: If the desired temperature is weather dependent, you
cannot change it on the home page.
To read out and overrule the active or next
scheduled desired temperature (in scheduled
mode or scheduled + reheat mode)
1 Go to the DHW tank temperature home page (Tank).
Result: or is displayed.
t
a
b
T
t
A1 A2 B1 B2 A1A1 A2 B1 B2 A1
During period… You can read out…
A1 The next scheduled action (a)
A2 The active action (a)
B1 The next scheduled action (b)
B2 The active action (b)
2 Press or to overrule.
Note: If the desired temperature is weather dependent, you
cannot change it on the home page.
Usage example: You need more hot water than
scheduled
If you are in the following situation:
Current time = 10:30
Next scheduled action of the DHW tank = Heat up to the preset
value (Eco; example: 55°C and sufficient for 2 persons) at 14:00
This evening you need hot water for 3 persons
Then you can do the following:
1 Go to the DHW tank temperature home page (Tank).
2 Overrule the next scheduled action by doing one of the
following:
Change from 55°C to 60°C (when defining hot water as
temperature)
Change from 2 persons to 3 persons (when defining hot
water as number of persons)
Advantages:
You will have sufficient hot water (= comfortable).
You do NOT have to change the schedule (= easy).
You do NOT have to activate the DHW tank booster mode
(= energy saving).
4.5.6 Using the DHW tank booster mode
About the DHW tank booster mode
You can use the DHW tank booster mode to immediately start
heating up the water to the preset value (Storage comfort). However,
this consumes extra energy.
To check if the DHW tank booster mode is active
1 Go to the DHW tank temperature home page (Tank).
2 Check the following:
In user profile = Basic: If is displayed, the DHW tank
booster mode is active.
In user profile = Detailed: If is selected, the DHW tank
booster mode is active.
To activate the DHW tank booster mode
(method 1)
1 Go to the DHW tank temperature home page (Tank).
2 Press for more than 2 seconds.
To activate the DHW tank booster mode
(method 2)
Prerequisite: User profile = Detailed
1 Go to the DHW tank temperature home page (Tank).
2 Press
to select .
Usage example: You immediately need more hot
water
If you are in the following situation:
You already consumed most of your hot water.
You cannot wait for the next scheduled action to heat up the
DHW tank.
Then you can activate the DHW tank booster mode.
Advantage: The DHW tank immediately starts heating up the water
to the preset value (Storage comfort).
4.6 Advanced usage
4.6.1 Using quiet mode
About quiet mode
You can use quiet mode to decrease the sound of the outdoor unit.
However, this also decreases the heating/cooling capacity of the
system. There are multiple quiet mode levels.
You can:
Completely deactivate quiet mode
Manually activate a quiet mode level until the next scheduled
action
Use and program a quiet mode schedule
Possible quiet mode levels
Level Description
Level 1 Most quiet. Under all circumstances,
performance will be reduced.
Level 2 Medium quiet. Under all circumstances,
reduced performance is possible.
Level 3 Least quiet. At colder ambient conditions,
reduced performance can be happen.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Daikin EHVH04S18CA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Daikin EHVH04S18CA

Daikin EHVH04S18CA Bedienungsanleitung - Deutsch - 28 seiten

Daikin EHVH04S18CA Bedienungsanleitung - Holländisch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info