554169
20
Zoom out
Zoom in
Vorherige Seite
1/24
Nächste Seite
5 Energy saving tips
User reference guide
20
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
4.9 Installer settings: Tables to be filled in by
installer
4.9.1 Quick wizard
Setting Default Fill in…
Backup heater configuration (only for unified backup heater)
[A.2.1.5]
BUH type 1 (1P,(1/2))
Preferential kWh rate power supply [A.2.1.6]
Preferential kWh rate 0 (LWT
control)
Space heating/cooling settings [A.2.1]
Unit control method 0 (In room)
User interface location 1 (1 LWT
zone)
Number of LWT zones 1 (1 LWT
zone)
Pump operation mode 1 (Sample)
Domestic hot water settings [A.2.2]
DHW operation Depends on
model
DHW tank heater Depends on
model
DHW pump 0 (No)
Thermostats [A.2.2]
Contact type main 2 (Thermo
ON/OFF)
Contact type add. 2 (Thermo
ON/OFF)
External sensor 0 (No)
Digital I/O PCB [A.2.2.6]
Ext. backup heat src 0 (No)
Solar kit 0 (No)
Alarm output 0 (Normally
open)
Bottom plate heater 0 (No)
Demand PCB [A.2.2.7]
Demand PCB 0 (No)
Energy metering [A.2.2]
External kWh meter 1 0 (No)
External kWh meter 2 0 (No)
Capacities (energy metering) [A.2.3]
Booster heater 0 kW
BUH: step 1 Depends on
model
BUH: step 2 Depends on
model
Bottom plate heater 0 W
4.9.2 Space heating/cooling control
Setting Default Fill in…
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode 0 (Absolute)
Set weather-dependent heating 25/40/15/−10
Set weather-dependent cooling 18/22/35/20
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode 0 (Absolute)
Set weather-dependent heating 25/40/15/−10
Set weather-dependent cooling 18/22/35/20
Leaving water temperature: Delta T emitter [A.3.1.3]
Heating 5°C
Setting Default Fill in…
Cooling 5°C
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT 0 (No)
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type 1 (Slow)
4.9.3 Domestic hot water control [A.4]
Setting Default Fill in…
Setpoint mode 2 (Scheduled
only)
Setpoint readout type 0
(Temperature)
Maximum setpoint Depends on
model
INFORMATION
It is recommended NOT to use the selection of ([60D]=0,
[A.4.1] Domestic hot water Setpoint mode=Reheat only) in
case of a domestic hot water tank without internal booster
heater.
The risk of space heating (cooling) capacity shortage/
comfort problems is significant (in case of frequent
domestic hot water operation, frequent and long space
heating/cooling interruption will happen).
4.9.4 Contact/helpdesk number [6.3.2]
Setting Default Fill in…
Contact/helpdesk number
5 Energy saving tips
Tips about room temperature
Make sure the desired room temperature is never too high (in
heating mode) or too low (in cooling mode), but always according
to your actual needs. Each saved degree can save up to 6% of
heating/cooling costs.
Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.
Use a weekly schedule for your normal space heating or cooling
needs. If necessary, you can easily deviate from the schedule:
For shorter periods: You can overrule the scheduled room
temperature. Example: When you have a party, or when you
are leaving for a couple of hours.
For longer periods: You can use the holiday mode. Example:
When you stay at home during your holiday, or when you go
away during your holiday.
Tips about leaving water temperature
In heating mode, a lower desired leaving water temperature
results in lower energy consumption and better performance. In
cooling, the opposite is valid.
Set the desired leaving water temperature in accordance with the
heat emitter type. Example: Under floor heating is designed for
lower leaving water temperature than radiators and heat pump
convectors.
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Daikin EHVX16S26CA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Daikin EHVX16S26CA

Daikin EHVX16S26CA Bedienungsanleitung - Deutsch - 28 seiten

Daikin EHVX16S26CA Bedienungsanleitung - Holländisch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info