About the lamps
1
About the water supply lamp
When the water supply lamp lights up, the Humidifying operation will stop (the Air purifying operation will continue) but the humidier ON/OFF
lamp will remain lit up.
After lighting up, the water supply lamp may be on and off a few times, however, this is normal (not a malfunction).
Stop operation of the unit and unplug the power supply, then ll the water tank with water and re-insert it into the unit. After a while, the water
supply lamp will be off and the Humidifying operation will resume.
Page 13
To stop the notication tone (3 long beeps) from sounding, change the settings.
Page 21
2
About the child proof lock lamp
When lit up, operations will be restricted. When buttons are pressed, only a tone (3 short beeps) will sound, preventing misoperation by small
children.
Page 19
3
About the dust/PM2.5 sensor lamp
After operation is started, the lamp will light green for the rst minute
(approx.) regardless of air impurity level.
If the responsiveness of the dust/PM2.5 sensor is poor, change the sensitivity
setting of the sensor.
Page 21
The responsiveness of the dust/PM2.5 sensor may be poor during FAN setting
“Turbo” or when airow is high in AUTO FAN MODE or MOIST MODE. The strong
airow causes dust to be drawn into the air inlets before it can be detected by the
dust/PM2.5 sensor. This is normal (not a malfunction).
Dust/PM2.5 sensor detection range
Detectable matter
house dust, tobacco smoke, pollen, mite droppings
and remains, pet hairs, diesel particulate matter
Sometimes detectable
steam, oil smoke
4
About the odour sensor lamp
If operation is started immediately after the power supply plug is inserted, the
lamp will light green for the rst minute (approx.).
If odour intensity levels are unchanging, the sensor may not respond even if there
is a strong odour in the air.
The following types of odours may not be detected:
pet odours that do not include ammonia, garlic odours, etc.
As odour perception varies by person, in some cases an odour may be sensed
even when the lamp is green.
If the odour bothers you, switch to manual airow rate, and select a high airow
rate.
Page 16
The basic sensitivity of the odour sensor will be determined by odour levels in the
rst minute (approx.) after the power supply plug is inserted every time. Insert the
power supply plug when the air is clean (odour-free).
Odour sensor detection range
Detectable matter
tobacco odours, cooking odours, pet odours, toilet
smells, waste smells, mould odour, sprays, alcohol
Sometimes detectable
sudden changes in temperature/humidity, steam, oil
smoke, gas emitted from combustion-based heating
devices
5
About the HUM monitor lamps
When the humidity level is below 30%, the “30” lamp will light up. When the humidity level is above 70%, the “70” lamp will light up.
The lamp will light up even when only the Air purifying operation is active.
At times the humidity level indicated on the unit may differ from other hygrometers.
This is because the ow of air causes temperature and humidity to vary throughout the room. Please consider the indications to be a rough
estimate of ambient humidity.
6
About the streamer lamp
During streamer operation, this lamp lights up. Streamer operation is conditional on the degree of air impurity.
If the hissing sound generated by the streamer discharge or the odour of ozone bother you, set streamer output to low.
Page 20
About the FAN and Humidity symbols
Symbol table *The size of the symbols varies in accordance with the airow rate setting.
FAN Humidity
Symbol
*
*
*
Setting Quiet Low Standard Turbo Low Standard High
Read First
01_EN_3P595628-1B.indd 10 2020/04/17 15:49:00
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Daikin MCK55WVM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Daikin MCK55WVM

Daikin MCK55WVM Bedienungsanleitung - Deutsch - 40 seiten

Daikin MCK55WVM Bedienungsanleitung - Holländisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info