AIR CONDITIONER OPERATIONS AND PERFORMANCE
A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is
restarted immediately after operation.
Select the position for the outdoor unit where it will not be subject to snow drifts, accumulation of leaves
or other seasonal debris. It is important that the air flow for the outdoor unit is not impeded as this will result in
reducing heating or cooling performance. During the heating mode (cooling only type without) and at sub-zero
temperatures, the water drained off the outdoor unit as a result of the automatic defrost may accumulate and
freeze. It is important that adequate drainage or a soak way is provided.
Power failure during operation will stop the unit completely.
The OPERATION lamp on the indoor unit will start flashing when power is restored.
To restart operation, push the ON/OFF button on the remote controller.
Lighting or a car wireless telephone operating nearby may cause the unit to malfunction. Disconnect the unit
with the power and then connect the unit with the power again. Push the ON/OFF button on the remote
controller to restart it.
For proper performance, run the air conditioner under the following temperature conditions:
Heating characteristics preheating operation
The air conditioner will not deliver warm air immediately after it is started. Warm air flows out after
approximately 5 minutes when the indoor heat exchanger warms up.
Warm air control
When the room temperature reaches the set temperature, the fan speed is automatically reduced to
prevent a cold draft. At this time, the outdoor unit will stop.
Defrosting
If the outdoor unit is frosted during heating operation, defrosting is started automatically (for approximately
5 to 10 minutes) to maintain the heating effect, and the PRE.-DEF. lamp is on.
The fans in both the indoor and outdoor units stop during the defrost operation.
During defrost operation, defrosted water is drained from the bottom plate of the outdoor unit.
Heating capacity
In the heating operation, heat is absorbed from outdoor and released into the room. that is so-called heat
pump system. When the outdoor temperature is too low, you are recommended to use another heating
apparatus in combination with the air conditioner.
Three-minute protection feature
Consideration for accumulated snow
Power failure
Air conditioner operating conditions
This will protect the machine. (cooling only type without)
If air conditioner is used outside of the above conditions, safety protection features may come into operation.
¡£
Outdoor temperature: 18 to 43 C
¡£
Outdoor temperature: 11 to 43 C
¡£
Outdoor temperature: -7 to 24 C
¡£
Room temperature: 17 to 32 C
¡£
Room temperature: 17 to 32 C
Room temperature: 0 to 27 C
Heating
operation
Cooling
operation
Dry
operation
Room relative humidity less than 80%. If the air conditioner operates in excess
of this figure, the surface of the air conditioner may attract condensation.
CAUTION
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Daitsu ASD9T2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Daitsu ASD9T2

Daitsu ASD9T2 Bedienungsanleitung - Portugiesisch - 13 seiten

Daitsu ASD9T2 Bedienungsanleitung - Spanisch - 13 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info