The Model 841 & 842 Timeswitches must be installed
by a competent electrician and the installation
should conform to IEE Wiring Regulations.
Installation & Wiring
1. Slacken the four xing screws, one in each corner of the unit, and
carefully separate the front and rear portions.
CAUTION: Do not allow either half of the unit to hang by the ribbon
cable as damage could be caused.
2. Remove the polystyrene packing piece from the top of the
transformer. It is marked ‘REMOVE’.
3. Select the desired xing position and observe the label ‘THIS WAY
UP’ inside the rear portion. The two halves will only assemble
correctly one way round.
4. Four xing holes are provided for attaching the rear portion to the
wall or mounting surface.
Conduit box adaptors as shown below are available if required.
Part No.: 8/3223 Double Gang Surface Box Adaptor
5. Surface cable entries to the units can be made from above, below
or from the left hand side. Conduit or recessed cable entry is
through the aperture in the rear moulding.
6. For surface cable entry remove the appropriate knock-out and
ensure one of the two cable clamps is positioned correctly.
7. Connections to the units should be made as shown below.
MODEL 841
MODEL 842
If the control circuit(s) are to operate at 230V then terminals L
& 1 (Model 841) and terminals L, 1 and 4 (Model 842) must be
linked, ensuring that the cable is sheathed and of a size to carry
the required load current.
If, however, the control circuit(s) are operating at other than 230V
then no link(s) shall be tted and in the case of Model 841 both
terminals 1 and 2 should be connected to the load.
841 & 842
Seven Day Pulsed Output Electronic Timeswitches
INSTALLATION INSTRUCTIONS
In the case of Model 842 terminals 1, 2 and 3 (if required) should
be connected to the load controlled by Channel 1 and terminals
4, 5 and 6 (if required) to the load controlled by Channel 2.
8. The unit is supplied set for a 5 second single pulse output. If a multi
pulse output is required, proceed as described in paragraph 10 (b).
If a number of pulses or the pulse duration is required to be different
from supplied, proceed as described in paragraph 11(b).
9. Upon completion of wiring plug in the ribbon cable ensuring the
polarised plug is fully inserted into the socket. Re t the front half
of the timeswitch ensuring correct alignment and that no cables
are trapped before re-tightening the screws.
10. TO CHANGE FROM SINGLE TO MULTI PULSE OUTPUT
(a) Remove the front portion of the unit as described in ‘Installation
and Wiring’ paragraph 1.
(b) A 2 position slide switch is provided on the rear of the printed
circuit board inside the front portion of the unit.
With the switch positioned OUT (as supplied) this provides a single
pulse output. Slide the switch IN to achieve a multi pulse output
(½ second on followed by ½ second off).
On Model 842 a 2 position slide switch is provided for each channel
to enable different types of pulsed output if required. The switch
relating to each channel is clearly marked.
11. RESETTING OF SWITCHING DURATION
(a) Remove the front portion of the unit as described in ‘Installation
and Wiring’ paragraph 1.
(b) The bank of four miniature rocker switches is mounted on the
printed circuit board inside the front portion of the unit.
When switch no. 1 is ‘on’ 1 second duration is set.
When switch no. 2 is ‘on’ 2 seconds duration is set.
When switch no. 3 is ‘on’ 4 seconds duration is set.
When switch no. 4 is ‘on’ 8 seconds duration is set.
When all 4 switches are ‘on’ the duration is
1 + 2 + 4 + 8 = 15 seconds.
Any combination of the 4 switches may be selected to set from 1
to 15 seconds in increments of 1 second.
If all 4 switches were ‘off’ there would be no output and so this
setting should be avoided.
(c) On Model 842, a bank of four miniature switches is provided
for each channel to enable different switching durations.
EXAMPLES
Cable
Entry
Aperture
2 xings for
double gang
surface box
Alternative 4 xings
for double gang
surface box
4 xings
for Mark 8
Timeswitch
Spare N L 1 2
230V, 50 Hz
Mains Supply
Link for 230V
control circuit
Output
(LOAD)
N L 6 5 4 3 2 1
230V, 50 Hz
Mains Supply
Link for
230V
control
circuit(s)
OFF ON
Channel 2
OFF ON
Channel 1
Slider Switch Posi-
tions
‘ON’
Duration
Slider Switch Posi-
tions
‘ON’
Duration
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
ON
OFF
1
23
4
NONE
Do Not Use
1 second
2 seconds
3 seconds
4 seconds
5 seconds
(As supplied)
6 seconds
7 seconds
8 seconds
9 seconds
10 seconds
11 seconds
12 seconds
13 seconds
14 seconds
15 seconds
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Danfoss 842 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Danfoss 842

Danfoss 842 Bedienungsanleitung - Englisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info