Site Preparation Overview
Consider the following factors before installing the scanner/scanning-scale and its optional
Remote Scale Display.
Ventilation Requirements —
The scanner operates without the use of a ventilation fan. As long
as there is adequate convective air flow and no major heat producing equipment in close
proximity, the unit’s housing provides adequate heat dissipation. The air temperature in the
checkstand around the scanner must not exceed 104°F (40°C).
Service Access Requirements —
Routine operations such as ‘zeroing’ and calibration do not
require removal of the scanner from the checkstand or disassembly of the product. The installer
should plan service access for the AC/DC Power Supply and cables.
Recommended Power Installation —
Since the typical grocery environment includes conveyor
belts and electric motors, care should be taken to ensure that the scanner has a supply of “clean”
power (power without excessive electrical noise).
Counter Preparation —
Since the majority of grocery checkout lanes are designed as “left-hand
take away,” the counter drawings in this section focus on this counter design. Simply reverse the
layout for a “right-hand take away” requirement. The unit scans equally well in either of these
two configurations.
Liquid Drainage —
Should a liquid spill occur, ensure that moisture can flow through the
checkstand without pooling.
Leveling
Plan ahead and provide screws/bolts in the checkstand mounts and a leveling guide
(board) to allow leveling of the scanner or scanning-scale within the counter. Use a 0.375” thick
board to replicate the mounting flange on the long scanner or scanning-scale, and adjust screws
or bolts until the board is flush within the counter. Use a 4.0” wide board stood on its end to
adjust leveling screws/bolts in rail support applications.
Cable Routing —
Placement of the scanning-scale should be planned to allow easy access to
other components as well as optimize communication between the scanner, the POS terminal
and the optional Remote Scale Display. Note that cables may drop straight down from the
scanner’s connector panel, or may be conveniently routed along the unit’s side using the
hardware provided. Do not route interface cables near any electrical motors or other sources of
electromagnetic interference.
Remote Scale Display Placement —
The customer, and checker in some instances, must be able
to easily view and read the Remote Scale Display (if one is present). Ambient light and
mounting height considerations are discussed later in this section.
Vertical Clearance —
Provision must be made to allow adequate space above the scanner bonnet
for removal and replacement of the All Weighs™ Platter (the L-shaped platter). Optimal
clearance permits the platter to be grasped at its top vertical edge and lifted for removal without
obstruction (such as a fixed keyboard mount or any type of enclosure). Should such an
enclosure be unavoidable, an alternate method of platter removal using two coins may be
employed, however a minimum vertical clearance of 1.5” (3.8 cm) MUST be provided
(reference
Figure 10). Another consideration is that the scan zone must be kept free of
obstructions such as enclosures, keyboard mounts, etc.
35

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Datalogic Magellan 9800i wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Datalogic Magellan 9800i

Datalogic Magellan 9800i Bedienungsanleitung - Englisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info