19
power cable is not in contact with metal parts at the back of the
cooker. The power supply cable must be located so that it does
not reach at any point the temperature of 75°C. Do not use tran-
sformers or shunters for connecting the appliance because
these could cause false contacts and dangerous overheating.
WARNING: It is the responsibility of the installer to ensure
that the standards referred to below are strictly adhered to.
The manufacturer declines all responsibility deriving from
the failure to apply these standards.
This appliance must be earthed.
TIPS FOR INSTALLATION
Before proceeding with connection, check that:
the electrical supply can support the load of the appliance (see
characteristics booklet, Fig. 3, page 3);
the electrical installation is fitted with an effective earth in accor-
dance with the regulations and provisions of the law;
the socket or the omnipolar cutout switch can be accessed easily
with the cooker fitted.
SUPPLY CABLE - SINGLE CAVITY COOKERS ONLY
If the cooker has a power cable fitted you will need to fit an
appropriate plug. Take care to connect as below:
L (Live) = brown cable
N (Neutral) = blue cable
E (Earth) = green/yellow cable
When the cooker has been installed, check that the power cable
is not in contact with the metal parts at the back of the cooker,
and that it does not at any point reach a temperature of 75°C.
CURRENT OPERATED EARTH LEAKAGE BREAKERS
Where the installation is protected by a 30 milliamp sensitivity
residual current device (RCD), the combined use of your cooker
and other domestic appliances may occasionally cause nuissan-
ce tripping. In these instances the cooker circuit may need to be
protected by fitting 100 mA device. This work should be carried
out by a qualified electrician.
REPLACEMENT OF THE MAINS POWER CABLE
To replace the cable, it is necessary to select the type indicated
on the table below and follow the instructions (Fig. 38):
disconnect the appliance from the network
unscrew the screws located on the rear of the appliance and
remove (Fig. 38)
unscrew the screw of the cable clamp
unscrew the screws in terminal C providing connection and
remove the cable
thread the new cable into the cable clamp
Connect the mains cable to the terminal following the diagram:
blue cable (neutral) connected to terminal N
brown live cable connected to terminal L
yellow/green cable connected to terminal X
tighten the screw of the cable clamp and refit the cooker taking
care not to crush the cables.
IMPORTANT:
When replacing the mains supply cable the installer must ensu-
re that the earth wire is longer than the live wires (Fig. 47) and
respect the prescriptions given below.
COMMENTS REGARDING OUR AFTER-SALES SERVICE
During the manufacture of your cooker, all requirements relating
to safety, as well as the international directives of the EEC, have
been respected. Furthermore, before leaving the factory, your
cooker was subject to a final check to ensure that all electrical
parts were operating correctly. We would be grateful if you would
also entrust the final work remaining on your cooker, namely its
connection to the mains, to a specialist, who must in this case be
a qualified installer. This is the only means of guaranteeing that
your cooker will operate appropriately and without danger.
fig. 46
fig. 47
fig. 48