TRIO DT 250 - TRIO DT 350 16/07/2015 - 300028005-001-04
Adjustment parameter DT - Reference
temperature difference
Adjustment range: 10 ... 20 K
Factory setting: 20 K
Switching-on difference: Non-adjustable value 10 K
Switching-off difference: Non-adjustable value 5 K
The regulator reads the temperatures measured by sensors S1 (TC)
and S2 (TS) and compares the resulting temperature difference with
the switching-on difference which is preset to 10 K. Regulation is
activated when the temperature difference T is equal to or greater
than the preset value. The display shows . When the value falls
below the preset 5 K switching-off difference, the regulator switches
off. The regulator tries to achieve a temperature difference of 20 K
(factory setting) between the collector and the tank to produce high
temperature hot water as rapidly as possible. To do this, it uses
dynamic speed control.
Adjustment parameter SZ - Zone changeover
temperature
Adjustment range: 20 ... 80 °C
Factory setting: 55 °C
If the temperature in the collectors reaches value SZ, the relay R2
closes.
If the temperature in the collectors is lower than value SZ, the arrow
"
flashes.
If the temperature in the collectors is higher than value SZ, the arrow
#
flashes.
We advise you to set the domestic hot water booster
temperature to 50°C. If the customer wants a higher
temperature, parameter SZ will have to be changed. SZ is
set to 55°C in the factory and must always be 5K higher
than the DHW booster circuit temperature setting(s).
If the domestic hot water boiler circuit is set at more than
50°C, SZ must be adjusted to 5K above this DHW circuit
temperature setting.
If the booster is electric, the resistance thermostat must be
set at 50°C.
Adjustment parameter SX - Set temperature of the
solar calorifier
Adjustment range: 20 ... 80 °C
Factory setting: 60 °C
Maximum tank temperature (emergency cut-off): Non-
adjustable value 85 °C
The set temperature Sx is the desired temperature for the solar
calorifier.
If the maximum tank temperature is exceeded, tank heating is
interrupted to prevent damage due to overheating. The display
shows and (flashing).
The higher the set temperature for the calorifier, the greater the
energy stored. Setting to 60 ... 75°C is suitable for normal use with
daily draw-offs.
In the event of prolonged absences (weekend, holidays):
- Reduce the calorifier temperature to 50°C
- Turn off the back-up (boiler or electrical resistance)
The installation is thus protected against overheating and the
longevity of the heat conducting fluid is conserved.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für De Dietrich DIETRISOL TRIO DT 350 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info