INSTALLATION
Leave sufficient space around the oven :
- 5 cm between the sides of the oven
and any walls or objects
- 14 cm above the oven
- 10 cm behind the oven.
LOCATION
BEFORE CONNECTION
•
Check whether your oven has suffered any damage during transport (deformed door or
door seal, etc.). If you see any signs of damage, contact your dealer before use.
•
Verify the power voltage. If there is a PERMANENT undervoltage (200-210 volts), consult your
electrical installer.
ELECTRICAL CONNECTION
•
The appliance should be installed at a distance of 85 cm above floor.
•
Place the oven on a flat and horizontal surface, away from any source of heat or
steam. To ensure the stability of the microwave oven, the front left foot is
adjustable (5 positions). Turn it to raise or lower the appliance.
•
Make sure that air may circulate freely around the oven.
•
Make sure that nothing obstructs the ventilation louvers at the back of the appliance.
•
Make sure the electrical plug will be accessible after installation.
•
Do not use your appliance immediatly (wait approx. 1-2 hours) after transfer from a cold
place to a warm place as condensation may cause a malfunction.
•
Your installation must be protected by a 16 Amp thermal fuse.
•
It is mandatory to use a power point with a ground terminal, connected in accordance with
current safety regulations.
•
In your electrical installation, provide a device that is accessible to the installer, capable of
separating the appliance from the mains power and whose contact opening is at least 3 mm
at all of the poles.
•
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.