7
2 / INSTALLING YOUR APPLIANCE
EN
••
ELECTRICAL CONNECTION
Single-phase 20A Meter
220-240V
~
50Hz
Electrical outlet
2 poles
++ eeaarrtthh
standard CEI 60083
220-240 V
~
Single-phase line
Power
supply cable
length 1.50 m
approx.
16A fuse or differential
circuit breaker
The appliance must be fitted correctly to
guarantee electrical safety. During fitting and
maintenance operations, the appliance must
be unplugged from the electrical grid. Fuses
must be switched off or removed.
The electrical connections are made before
the appliance is installed in its housing.
Ensure that:
- the electrical installation has sufficient
voltage,
- the electrical wires are in good condition,
- the diameter of the wires complies with the
installation requirements.
Your oven must be connected with a
(standard) power cable with 3 conductors of
1.5mm
2
(1 live + 1 neutral + earth) which must
be connected to a 220-240V
~
single-phase
grid by means of a 1 live + 1 neutral + earth
CEI 60083 standard power socket or via an
all-poles cut-off device in compliance with the
installation rules.
Warning
The safety wire (green-yellow) is
connected to the appliance’s
terminal and must be connected to the
earth terminal of the electrical set-up.
You must enable the appliance to be
disconnected from the supply network after
installation.
Disconnection can be enabled by ensuring
that there is an accessible power plug or by
incorporating a switch into the fixed wiring in
compliance with the installation rules.
The fuse in your set-up must be 16 amperes.
If the power cable is damaged, it should be
replaced by the manufacturer, its after-sales
service department or a similarly qualified
person to avoid danger.
OVEN WITH PYROLYSIS
FUNCTION