How do you install your oven?
Monophase 20A Counter
220-240 V ~ 50 Hz
Electrical outlet
2-prong receptacle
+ ground lead
CEI Standard 60083
Monophase line 220-240 V ~
ELECTRICAL CONNECTION
Power cable
approximately
1.5 m in length
16A fuse or differential
circuit breaker
Before making the connection, ensure that the wires in your elec-
trical installation have enough cross-sectional area to properly
supply electricity to the appliance.
The fuse in your set-up must be 16 amperes.
The electrical connection should be performed before the appliance is installed in
the cabinet.
• The oven must be connected with a power cable (standardised) with three 1.5
mm
2
conductors (1 ph +1 N + ground) that must be connected to a monophase
220-240 V network via a CEI 60083 standardised receptacle (1 ph +1 N + ground
lead) or in accordance with installation rules. The safety wire (green-yellow) is
connected to the appliance's terminal and must be connected to the ground
lead of the electrical set-up.
• In the case of connections with an electric receptacle, it must remain accessible
after installation of the appliance.
• The oven's neutral conductor (blue wire) must be connected to the network's
neutral conductor.