This appliance should be installed by
a qualified technician / installer.
Prior to installation, ensure that the
local distribution conditions (nature
of the gas and gas pressure) and the
adjustment conditions of the
appliance are compatible.
The adjustment conditions are stated on a
label in the wallet and also on the packa-
ging.
Since this appliance is not connected to a
combustion products evacuation device, it
must be installed in accordance with cur-
rent installation regulations and used in a
well-ventilated place. Particular attention
should be given to the relevant require-
ments regarding ventilation.
Installing your hob in all simplicity
31
On this subject, combustion can take place
only if oxygen from the air is present, so
this air must be constantly renewed and
the combustion products must be evacua-
ted (a minimum air input of 2 m3/hour per
kw of gas energy is required).
E.g. 60 cm model - 2 gas burners :
Total power :
3 + 1,5 = 4,5 kW.
4,5 kW x 2 = 9 m3/h minimum airflow.
These hobs have type X protection (in
accordance with standard EN 60.335.2.6)
against overheating of cupboards and
Class 3 for installation itself (in
accordance with standard EN 30.1.1).
Fitting recommendations
Depending on
cupboard
Cut-out
56 cm 49 cm
Height Width
Depth
Outside
dimensions above
the work surface
65 cm 52 cm 5 cm
Outside
dimensions below
the work surface.
55 cm 47 cm 6,5 cm
Disconnect the apparatus before intervention