22
Installing your hob in complete safety
- When the power is switched on, or
after a long power failure, a light code
appears on the control panel. This di-
sappears automatically after about 30
seconds or as soon as any touch
control is touched on the
panel. This is normal, as the display is
for use by the after-sales service when
required. The user must not take this
into account under any circum-
stances.If the unit has a 3 phase 400
V2N connection, and is not working
correctly, check that the neutral wire is
correctly connected.
This precaution should also be taken
for all your other electronic apparatus.
● Your hob's electrical characteristics
Operating voltage............................................................220-240 V
∼∼
50 Hz
Total energy consumption....................................................10800 W
E
lectrical connections
The unit must be installed so that the mains
plug is easily accessible.
Hobs must be connected to the mains
by:
- A Type H05RRF power cable with three
2.5mm² or five 1.5mm² conductors
(including a green/yellow earth wire).
- A plug that complies with the CEI
60083 announcement or an all-pole cu-
tout unit with contacts that open by at
least 3mm.
This appliance meets European
Directives 73/23/CEE and 89/336/CEE.