15
Installing your hob in complete safety
Connection
These hobs are delivered with type H 05 VVF power cable (1.5mm²) with 3/5 conductors (including a
green/yellow earth wire), which must be connected to the power supply via a plug that complies with pu-
blication CEI 83 or an all-pole cut-out unit with contacts that open by at least 3mm.
If the cable is damaged, it must be replaced by the manufacturers, their After Sales Service or another
similarly qualified person for avoiding any possible risk of accident.
230 V
∼∼
50 Hz
Total energy consumption:
DTV314.......6,2 kW
DTV315.......6,9 kW
DTV318.......7,2 kW
Neutral
Earth
Phase
N
L
fuse : 32 Amp
Neutral
Earth
Phase 2
Phase 1
N
L1
L2
NOTE
Separate the 2
phase wires L1
and L2 before
connecting
Blue
Green/yellow
Black
fuse : 16 Amp
Green/yellow
Blue
Black
Brown
Brown
230 V
230 V
230 V
230 V
After a prolonged power cut, an unexpected light
may come on. Simply press any button and it will