607663
30
Zoom out
Zoom in
Vorherige Seite
1/40
Nächste Seite
Code no. Description Checking / solution
B40
Measurement error on the domestic hot water
temperature sensors.
Remarks:
4 This message is only displayed on initial
commissioning.
4 This message disappears after 10 minutes or when
you press the B key.
4 Contact the professional who takes care of
maintenance of the appliance.
Err BuS
No communication between the control panel and the
PCU board.
4 Contact the professional who takes care of
maintenance of the appliance.
InIt12
No communication between the control panel and the
PCU board.
4 Contact the professional who takes care of
maintenance of the appliance.
If the causes of the problem are still present after several attempts at
automatic start-up, the appliance goes into lockdown mode (also
called failure).
¼see chapter: "Messages (type code EXX)", page 29
7.1.2. Messages (type code EXX)
1. The display shows :
- The symbol (!)
- The symbol
V
- The fault code (for example
E02
).
2. After correcting the failure, press the
V
key for 2 seconds. If
the error code continues to display, search for the cause in the
error table and apply the solution.
Code no.
Description Checking / solution
E00
The parameter storage unit on the PCU electronic board is
defective
4 Contact the professional who takes care of
maintenance of the appliance.
E01
The middle DHW temperature sensor is short circuited
Note: DHW production is not covered
4 Contact the professional who takes care of
maintenance of the appliance.
E02
The middle DHW temperature sensor is open
Note: DHW production is not covered
4 Contact the professional who takes care of
maintenance of the appliance.
E04
The room temperature sensor is short circuited
Note: DHW production is handled by back-up if back-up enabled
4 Contact the professional who takes care of
maintenance of the appliance.
E05
The room temperature sensor is open
Note: DHW production is handled by back-up if back-up enabled
4 Contact the professional who takes care of
maintenance of the appliance.
E06
The evaporator temperature sensor is short circuited
Note: DHW production is handled by back-up if back-up enabled
4 Contact the professional who takes care of
maintenance of the appliance.
E07
The evaporator temperature sensor is open
Note: DHW production is handled by back-up if back-up enabled
4 Contact the professional who takes care of
maintenance of the appliance.
E08
Malfunction on the defrosting function
Note: DHW production is handled by back-up if back-up enabled
4 Contact the professional who takes care of
maintenance of the appliance.
E09
The low pressure pressure switch alarm sounds for more than
120 seconds
Note: DHW production is handled by back-up if back-up enabled
4 Contact the professional who takes care of
maintenance of the appliance.
E10
The low pressure pressure switch alarm has been tripped more
than 3 times during the last 24 hours
Note: DHW production is handled by back-up if back-up enabled
4 Contact the professional who takes care of
maintenance of the appliance.
C003212-B
2"
1
4
3
4
1
2
MENUMODE
7. Troubleshooting TWH 200E TWH 300E TWH 300EH
29
16/09/2015 - 7605313-001-06
30

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für De Dietrich Kaliko TWH 300EH wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von De Dietrich Kaliko TWH 300EH

De Dietrich Kaliko TWH 300EH Bedienungsanleitung - Deutsch - 40 seiten

De Dietrich Kaliko TWH 300EH Installationsanweisung - Englisch - 80 seiten

De Dietrich Kaliko TWH 300EH Bedienungsanleitung - Holländisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info