Troubleshooting
PROBLEM CAUSE REMEDY
The air conditioner
does not come on
• there is no current
• it is not plugged into the mains
• The safety device has tripped
• wait
• plug into the mains
• Contact your service centre
The air conditioner
works for a short
time only
• the air exhaust hose has a constriction
• the air exhaust hose is blocked
• there are bends in the air exhaust hose
• position the exhaust hose cor-
rectly
• check there are no obstacles
obstructing air discharge
• eliminate the bends
The air conditioner
works, but does not
cool the room
• window open
• there are heat sources in the room (burner,
lamp, etc)
• ithe exhaust hose is detached
• air filter clogged
• the air conditioner is not powerful enough for
the conditions or size of the room
• close the window
• eliminate the heat source
• connect the exhaust hose
•clean or replace the filter
•clean or replace the filter
Particular odour in
the room
• the filter is clogged
The air conditioner
does not operate
for about 3 minutes
after turning it on
• The safety device has tripped • wait for three minutes
// PP FF //
appears
on the display
• See self-diagnosis section
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with the following
code:
Green and yellow: Earth
Blue: Neutral
Brown: Live
As the colours of the wires in the mains lead may not correspond with the
coloured markings identifying the terminals in your plug, proceed as fol-
lows:
The green and yellow wire must be connected to the terminal in the plug
marked with the letter E or the earth symbol or coloured green or
green and yellow.
The blue wire must be connected to the terminal marked with the letter N
or coloured black.
The brown wire must be connected to the terminal marked with the letter L
or coloured red.
ELECTRICAL CONNECTION (UK ONLY)
A) If your appliance comes fitted with a plug, it will incorporate a 13
Amp fuse. If it does not fit your socket, the plug should be cut off from
the mains lead, and an appropriate plug fitted, as below.
WARNING: Very carefully dispose of the cut off plug after removing
the fuse: do not insert in a 13 Amp socket elsewhere in the house as
this could cause a shock hazard.
With alternative plugs not incorporating a fuse, the circuit must be
protected by a 15 Amp fuse.
If the plug is a moulded-on type, the fuse cover must be re-fitted when
changing the fuse using a 13 Amp Asta approved fuse to BS 1362.
In the event of losing the fuse cover, the plug must NOT be used until
a replacement fuse cover can be obtained from your nearest electri-
cal dealer. The colour of the correct replacement fuse cover is that as
marked on the base of the plug.
B) If your appliance is not fitted with a plug, please follow the instruc-
tions provided below: